INSTRUCTIONS - INTERFIT
PROJECTOR LIFT – FVI and HTI Series
6500105 Connect IP 4 Core Motor Controller
6500105 Connect IP 4 Core Motor Controller
Inputs on Motor Controller
All inputs on module 1 are accessed by removing right hand end cap of screen canister
1. Contact Close Input
1. CONTACT CLOSE INPUT
Contact Close Input for local control
Requires 2 x Momentary contacts duration minimum 50 milliseconds
Dedicated contact for Up & Down
Stop command is close opposite travel contact or both Up & Down together
2. DC Trigger Input
a. Contact Close Input for local control
b. Requires 2 x Momentary contacts duration minimum 50 milliseconds
c. Dedicated contact for Up & Down
d. Stop command is close opposite travel contact or both Up & Down together
a. Down command is sent when a DC Voltage of 3 Volts @ 1mA minimum is applied to
input
b. Up command is sent when a DC Voltage of less than 1.0 Volts DC @ 1mA is applied
to input.
c. Maximum cable length 75 meters approximately based 24 AWG gauge cable
2. DC TRIGGER INPUT
Down command is sent when a DC Voltage of 3 Volts @ 1mA minimum is applied to input, a
Up command is sent
Up command is sent when a DC Voltage of less than 1.0 Volts DC @ 1mA is applied to input,
a Down command is sent
Maximum cable length 75 meters approximately based 24 AWG gauge cable
4
Continued Over.../