Introduction

Purpose
This manual provides installation instructions for the Distribution Box (D-Box)
PA0306XX20. The D-Box provides an interface between Gilbarco
with two-wire current loop and one of the following:
• Dispensing units
• CRIND
Note: Current D-Boxes are available only with dual interface boards. Early D-Boxes were
Do not install this equipment unless you have proper training for installing equipment in a
hazardous location.
Intended Users
This manual is intended for Gilbarco trained and certified Authorized Service Contractors
(ASCs).

Table of Contents

Topic
Required Tools
Following tools are required for installing the D-Box:
• Drill
• Megger
• Phillips
• Slotted-tip Screwdriver
MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015
Distribution Box PA0306 Installation Instructions
devices
®
available with single or dual interface boards.
IMPORTANT INFORMATION
Tester
®
Screwdriver
®
Page
1
4
6
8
12
15
MDE-3116E
November 2015
consoles and controllers
®
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the PA0306 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GILBARCO VEEDER-ROOT PA0306

  • Page 1: Table Of Contents

    Appendix: Rewiring Transformer for Smaller Sites Required Tools Following tools are required for installing the D-Box: • Drill • Megger Tester ® • Phillips Screwdriver ® • Slotted-tip Screwdriver MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015 Page 1...
  • Page 2 (M07555 Power Supply Only) • Encore and Eclipse Installers • Engineering Diagrams FE-364 Field Wiring Diagram Encore 300 • Encore and Eclipse • Encore and Eclipse Installers • Engineering Diagrams Page 2 MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015...
  • Page 3 Occupational Safety and Health Administration Printed Circuit Board Point of Sale Radio Frequency Interference Submersible Turbine Pump Technical Assistance Center Two-wire Interface Underwriters Laboratories ® Unshielded Twisted-pair Voltage Alternate Current MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015 Page 3...
  • Page 4: Important Safety Information

    • Use of safety tape, cones, or barricades at the affected DEF is non-flammable. Therefore, explosion and fire safety unit(s) warnings do not apply to DEF lines. • A total electrical shut-off of the affected unit(s) Page 4 MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015...
  • Page 5  Subpart S of 29 CFR Part 1910 - Electrical Hazards, 29 CFR Part 1910.333 contains specific Lockout/Tagout provision for electrical hazards. MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015 Page 5...
  • Page 6: Overview

    The two boards installed in a D-Box can be configured as either of the following: • Two separate inputs with each input controlling eight data loops. • One input controlling 16 data loops. Page 6 MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015...
  • Page 7 1 - 1 PCB (8 loops)  2 - 2 PCBs (16 loops) Graphics/Housing: 0 - USA/Canada 1 - Europe Source Voltage: 1 - 230 VAC 50/60 Hz 0 - 115 VAC 50/60 Hz MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015 Page 7...
  • Page 8: Preliminary Preparation

    For Canadian installations, use the Canadian Electrical Code CSA C22.2. The site must be equipped with electric service allowing compliance with all installation requirements of a complete fueling system. Page 8 MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015...
  • Page 9 The PA0306 D-Box is suitable for use over hazardous locations. The box must be installed at least 18 inches above the floor. Locate the D-Box in an area which minimizes the possibility of liquids being spilled onto it.
  • Page 10 Note: Isolated Receptacle - User to supply proper receptacle to meet local electrical code requirements. The receptacle providing power to the PA0306 must be a properly isolated ground receptacle (Hubbell #IG 5261 or the equivalent). The green grounding screw must be attached to the grounding conductor.
  • Page 11 However, twisted pair wiring is recommended for existing wired stations known to have communications problems between the console and dispensers. When pulling wires, be careful to avoid damage to the insulation. MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015 Page 11...
  • Page 12: Installing D-Box

    Change the jump jacks (JP1 through JP8) one at a time to the NORMAL position (for wiring connections, see Figure 3 page 13). Verify operation of the card readers and/or dispensing units. Replace the D-Box cover and secure with screws. Page 12 MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015...
  • Page 13 2 boards, 2 inputs, 8 loops, 30 mA for Non-Gilbarco UL Listed dispensers. JP13B – In JP13B – In Interfaces to 45 mA controllers. JP11B – In JP11B – In JP10 – In JP10 – In MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015 Page 13...
  • Page 14 Cut and strip supplied loops for desired number of field connections. Note: If unused pigtail loops are cut, the exposed ends must be capped with wire nuts. Wire Nuts 14 AWG Field Wiring R19263 Pigtail Cable Assembly Page 14 MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015...
  • Page 15: Appendix: Rewiring Transformer For Smaller Sites

    Disconnect dispenser-loop wiring, POS cables, and transformer power from the D-Box boards. Remove the board tray to expose the transformer. Remove the shield that surrounds the transformer. Remove the transformer from the mounting studs. MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015 Page 15...
  • Page 16 5) from the side of the transformer opposite the wiring going to the AC receptacle (see Figure Figure 5: Removing Loop-back Connection Figure 6: AC Receptacle Wiring To the AC receptacle no modifications needed Page 16 MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015...
  • Page 17 Reinstall the transformer onto its studs and reassemble the transformer shield and D-Box board tray. Reinstall the AC power cord to the D-Box. Plug the AC cord back into the isolated and dedicated receptacle. Remove the lockout/tagout tags. MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015 Page 17...
  • Page 18 Underwriters Laboratories Inc. ® ® © 2015 Gilbarco Inc. 7300 West Friendly Avenue · Post Office Box 22087 Greensboro, North Carolina 27420 Phone (336) 547-5000 · http://www.gilbarco.com · Printed in the U.S.A. MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015...