Replace A Fan (Procedure A); Remove A Cooling Fan; Install A Cooling Fan - YASKAWA AC Drive Manual

Table of Contents

Advertisement

5 Replace Cooling Fans and Circulation Fans

Replace a Fan (Procedure A)

DANGER
drive. Before servicing, disconnect all power to the equipment and wait for the time specified on the warning label
at a minimum. The internal capacitor stays charged after the drive is de-energized. The charge indicator LED
extinguishes when the DC bus voltage decreases below 50 Vdc. When all indicators are OFF, remove the covers
before measuring for dangerous voltages to make sure that the drive is safe. If you do work on the drive when it is
energized, it will cause serious injury or death from electrical shock.
CAUTION
of 15 minutes, then make sure that the heatsink is cool before you replace the cooling fans. If you touch a hot
drive heatsink, it can burn you.
NOTICE
on the fans, replace all the fans to increase product life. If you install the fans incorrectly, it can cause damage to
the drive.

Remove a Cooling Fan

1.
Push the tab on the back side of the fan finger guard and pull up to remove the fan finger
guard from the drive.
A - Fan finger guard
2.
Pull the cooling fan straight up from the drive. Remove the protective tube on the power
supply connector and disconnect the connector to remove the fan from the drive.
A - Cooling fan

Install a Cooling Fan

Reverse the removal procedure to install a cooling fan.
6
Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized
Burn Hazard. Do not touch a hot drive heatsink. De-energize the drive, wait for a minimum
Use the instructions in this manual to replace the cooling fans. When you do maintenance
Figure 5.1 Remove the Fan Finger Guard
Figure 5.2 Remove the Cooling Fan
B - Protective tube
YASKAWA TOEP C730600 0FA Fan Replacement Procedure

Advertisement

Table of Contents
loading

Table of Contents