E-Gate max

Menu M05 (Ethernet output display)

The sending of data via the Ethernet is set with this menu. Data can be sent via a maximum of
2 Ethernet lines.
Ethernet output 1 display
Ethernet output 2 display
Press [Edit]
and turn the encoder dial
Press [Edit] again and turn the
encoder dial
Select the source:
Display:
Meaning:
off
No source (no data is sent via the
Ethernet line)
DMX A
DMX input A
DMX B
DMX input B
OUT A
DMX output A
OUT B
DMX output B
OUT C
DMX output C
OUT D
DMX output D
Select the universes 1 through 32 to be sent:
Display:
Meaning:
UNI 1
Universe 1
...
through
UNI 32
Universe 32
Local operation
ETH OUT 1
DMX A ->
UNI
ETH OUT 2
DMX B ->
UNI 32