Connection to water supply

There must be a shut-off tap on the water
supply pipe. The shut-off tap should be
positioned above the work surface or at
the front of the sink unit.
The water supply pipe has a connection
with a 1/2" or 3/4" internal thread depend-
ing on country.
When the installation is complete, the
shut-off tap should be opened to allow the
pressure to settle for a while and to check
that all connections are tight.
NB!
It is recommended that connection should
be to cold water.

Connection to electricity

A dishwasher fitted with a lead and plug
must be connected to an earthed socket.
Repairs and maintenance relating to
safety or performance must be carried out
by a qualified professional.
Technical data
See the type plate on the right hand side of
the door.
Connection to drainage
NB!
The hose must be fastened level with the
underside of the work surface.
Max 950 mm
Min 350 mm
32
CAUTION!
The lead must be disconnected or the
socket voltage-free while the work is car-
ried out!
Connection to drainage
The drain hose is routed to a connection
nipple at the sink's water trap, as illustrated
above. Note that the hose must be fas-
tened level with the underside of the sink
unit – otherwise the dishwater from the
sink will run down into the dishwasher, as
illustrated.
The drain hose is threaded onto a cone-
shaped connecting pipe at the sink unit's
water trap. The cone-shaped pipe must be
cut to an internal diameter of at least 16 mm.
The drain hose may be lengthened by a
maximum of 3 m. Any connections and
connecting pipes must have an internal di-
ameter of at least 16 mm.
No part of the drain hose may be more
than 950 mm above the floor.
The hose must not be routed directly to the
floor drain or similar. In such cases, the
hose can act as a siphon and empty the
dishwasher.
The hose must always discharge at least
350 mm above the floor.
Max 950 mm
Min 350 mm
Max 950 mm
Min 350 mm