Summary of Contents for Freemie Collection Cups FG041
Page 1
IMPORTANT Read this manual prior to use This Freemie Breast Pump Collection System is a single user, reusable system that you may use throughout the first year of your baby’s life, and beyond. This manual contains important information for the proper sanitization, use and care of your Freemie system. Please visit our...
Philips Avent / Ameda / Lucina / Evenflo / Ardo Spectra / Unimom Spare Parts & Customer Service Indications for use: The Freemie Breast Pump Collection System is intended to be used in conjunction with an approved powered breast pump for the purpose of expressing human milk.
Page 3
If you have any concerns about your health, or experience any pain while nursing or using any breast pump, consult your health care or lactation professional immediately. Dr. Dao, Dao Health and Freemie User Manual do not give medical or lactation advice, or make diagnoses.
This could cause leakage, loss of suction, and milk to flow into tubing. • Do not overfill Freemie cups, as this may cause milk to flow into the tubing. You may hear a faint bubbling sound as the Freemie is filling. There is a risk of overfilling if you are hearing impaired or use Freemie in a noisy environment.
Freemie Breast Pump Collection System Two cup assemblies are included. Additional funnel sizes available at www. Freemie.com Parts Included Breast Funnel (2) Valve Bases Deluxe FG029 25mm - FG024 (2) 28mm - FG025 (2) (2) Natural Shape Cups Standard FG027...
Preparing Freemie for First Use Disassemble and clean Freemie prior to first use. NOTE: Some parts must be boiled initially, otherwise the parts may not fit securely. Follow the instruction below for how to sanitize these parts. Unsnap cup from funnel Pull valve base off funnel Remove valve from valve base Sanitize Parts Do not steam sterilize or dishwash any Freemie components.
Assembling Freemie Cups Always wash hands prior to assembling Freemie. All parts must be completely dry, correctly positioned, and secure. Inspect the device before each use for signs of wear or damage and replace parts if signs of wear are noted.
Connecting to Compatible Pumps See Compatible Pump Diagrams section (pages 15 - 20) for further information on how to connect your Freemie Collecton Cups to your approved compatible pump. Additionally, be sure to review your breast pump’s User Manual.
The Perfect Bra Fit Bra fit is critical to the proper use of this device. 1. Before choosing a bra, pump with the Freemie using your hands to hold in place. Consider how much pressure you normally apply against your breasts to pump.
If you regularly produce more than 8 ounces at a time, stop pumping when Freemie is full and empty device. (See page 11, When Your Are Done Pump- ing) Alternatively, if you have a second Freemie set, switch out full Freemie...
• Bending over or reclining during use, or overfilling may cause leaking, loss of suction, or milk to flow into tubing. • Empty Freemie when full and remove immediately after pumping. • If milk flows into tubing immediately turn off pump and disconnect from pump.
3. Carefully remove cups from your bra. 4. Freemie cups may be set flat on a table until ready to transfer to a storage container. 5. When Freemie cups are full, do not lay flat on back unless tubing is disconnected.
Pouring milk into a container Practice with water first to achieve successful transfers. Handle a full Freemie cup with care. Milk can spill out of the Breast Funnel. Removal of tubing creates pour spout for transferring milk into storage containers.
Breast Funnel, visit Freemie.com to order the right size Freemie for you. • Each Freemie holds up to 8 ounces of milk. If you pump more than this at one time, you need to empty and clean the device to continue pumping. (see page 12)
•Try a tighter fitting bra to ensure that the bra is able to support and maintain an adequate seal and hold Freemie in an upright position. Consider trying a sports bra. (see page 9) • Philips Avent, Ameda, & Lucina Only: Check that barrier is properly oriented. (see page 4) Milk in Tubing •Always make sure device is placed in bra with tubing and pour spout at the 12 o’clock posi-...
Medela, Lactina, Personal, Symphony and Pump in Style are trademarks of Medela AG Corporation Switzerland. Hygeia, EnJoye, and Q are trademarks of Hygeia. Medela and Hygeia do not endorse and are not affiliated with Freemie Collecton Cups or DAO Health.
Yours are trademarks of Ameda. Lucina and Melodi Prime are trademarks of Lucina. Evenflo is a trade- mark of Evenflo Feeding, Inc. Ardo and Calypso are trademarks of Ardo Medical AG, Switerland. Philips, Ameda, Lucina, Evenflo and Ardo do not endorse and are not affiliated with Freemie Collection Cups or DAO Health.
Compatible Pump Connection Diagrams Double Electric Breast Pump NUK is a registered trademark of Mapa GmbH, Zeven, Germany. NUK does not endorse and are not affiliated with Freemie Collection Cups or DAO Health.
M1, S1, S2, 9 Plus Forte Spectra is a trademark of Spectra UnzinMedicare Co. Unimom is a trademark of Unimom. Spectra and Unimom do not endorse and is not affiliated with the Freemie Breast Pump Collection System or Dao Health.
Need help?
Do you have a question about the Collection Cups FG041 and is the answer not in the manual?
Questions and answers