``POWER LIGHT`` SERIES FOR NON MAINTAINED EMERGENCY LUMINAIRES

TECHNICAL CHARACTERISTICS

OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Pb)
BATTERY PROTECTION
INDICATIONS - CONTROLS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
GENERAL
These luminaires are used indoors (ta 40 C)
where emergency light is needed. Each
luminaire must be permanently connected to
mains power supply. In normal operation the
power and charge indicators are on to
indicate that the batteries are charging. In
case of a mains power supply failure the
power and the charge indicators turns off and
the luminaire
will
automatically in emergency mode. When the
mains power supply is restored the device
turns to normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions οn page 3.
OPERATION
When the device is powered from the mains
and the battery(ies) is (are) connected, the
'power' and 'charge' indicators are ON. The
'charge'
indicator
charging operation. If it does not light,
probably, the batteries are disconnected. If it
does
not
light
connected, then contact the technician. The
power
indicator
connection to the mains. The TEST button,
Page 1 from 3
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Thank you for your trust in our products
Olympia Electronics - European manufacturer
light the spot lamps
indicates
the
battery
and
the
batteries
confirms
the
proper
(for LED MODULE Specifications see page 2)
GRL-21/H/90
220-240V AC/50-60Hz
13.3W/14VA
12V/7Ah
From overcharge and deep discharge
Power indicator, battery charge indicator, TEST button
90 min
White power LEDs
3200lm
5 to 40 C
Up to 95%
Aluminum, ABS/PC, PC
302 x 94 x 350 mm.
4100gr.
3 years (1 year for the battery)
has a dual use. If pressed instantlly while the
o
device is connected to the mains, the device
simulates the power interruption, by lighting
the lamps for 3''. In that way, we can control
the driver circuit of the lamps and the lamps as
indicated in paragraph 3 in the text below.
DIMMING OPTION
When the luminaire is in emergency mode, with
corresponding pressings of the button, we can
choose the illumination of 100%, 50%, 33% or
turned off, in order to increase the autonomy
duration. This option is canceled when the
network is restored.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or
testing must be done by authorized
personnel only.
2. The device must be connected to the
mains power supply through a fuse
dependent by the total amount of the line's
power load.
3. It is suggested to check every month the
indication LED for battery charging, and by
are
pushing instantly the TEST button to check
the emergency circuit and the lamps. If the
luminaire does not light,
GRL-21/H/180
2x12V/7Ah
24h
180 min
IP42
o
6300gr.
contact the
923021042_09_004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POWER LIGHT Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Olimpia electronics POWER LIGHT Series

  • Page 1 ``POWER LIGHT`` SERIES FOR NON MAINTAINED EMERGENCY LUMINAIRES TECHNICAL CHARACTERISTICS (for LED MODULE Specifications see page 2) GRL-21/H/180 GRL-21/H/90 OPERATION VOLTAGE 220-240V AC/50-60Hz MAXIMUM POWER CONSUMPTION 13.3W/14VA BATTERY (Pb) 12V/7Ah 2x12V/7Ah From overcharge and deep discharge BATTERY PROTECTION Power indicator, battery charge indicator, TEST button INDICATIONS - CONTROLS CHARGING TIME MINIMUM AUTONOMOUS DURATION...
  • Page 2 Battery replacement installer. It can be done only by a competent person 4. It is suggested to check every 6 months and after the mains interruption. the minimum autonomy duration by 1. Follow the step 2 of the installation disconnecting the mains power supply. procedure.
  • Page 3 INSTALLATION PROCEDURE (For wall mounting only) Mounting holes Fig. 1 Cover retaining screws Power Charge indicator indicator TEST button 1. Install the included mounting accessories to hook the device from the mounting holes (Fig. 1). 2. Unfasten the 4 mounting screws to remove the front plastic cover (Fig. 1). 3.

This manual is also suitable for:

Grl-21/h/90Grl-21/h/180

Table of Contents