Download Print this page

Olimpia electronics BS-465 Manual page 3

Pstn telephone dialer card for bs-468 panels

Advertisement

TELEPHONE SRC
In this option we can enter the telephone
number of te SRC center.
ID PANEL
Entering this menu we insert the four digit
password of our panel for the SRC. This
code is unique for each panel.
NOTIFY INCIDENTS
We can choose which incidents the SRC will
send to us.
COMMUNICATION CHECK
The panel has the capability of sending a
test signal to the ARC in order to report to it
the good operation.
The send period for the test signal can be
selected as follows:
- every 4 hours
- every 8 hours
- every 24 hours
There is also an option to disable the test
signal.
COMMUNICATION TEST
A f t e r e n t e r i n g t h e s e e l e m e n t s w e c a n
conduct a communication test using the BS-
466 keyboard.
After a few seconds we are informed if the
communication test was successful or not.
CID SIGNALS
The BS-468 panel sends the following signal
to the ARC with there respective codes:
1110/3110 - Fire
1120/3120 - Panic
1122/3122 - Silent Alarm
1130/3130 - Alarm
1137/3137 - Tamper alarm
1300/3300 - Fault
1301/3301 - AC power fault
1302/3302 - Battery fault
1303/3303 - RAM memory fault
1330/3330 - Peripheral device fault
1401/3401- Disarm /Αrm
1406
- Cancel alarm
1461/
- Wrong code entry
1601/
- Communication check
Page 3 from 4
1627/
- Technician menu entry
1628/
- Exit from technician menu
If the source of the event is :
001 .. 024 – Zone 01 .. 24
100 – Panel
101 – Battery
102 – PC
103 – GSM
104 – PSTN
105 – Remote controller
111 .. 116 – Outputs
132 .. 135– Expansion 02 .. 05
142 .. 149 – Keyboard 02 .. 09
151 .. 160 - Timers 01 .. 10
200 – Main user code
201 – Technician code
202 .. 252 – User code 01.. 50
Whereas the sections are referred t o as:
00 - Panel
01 - Section A
02 - Section B
03 - Section C
921465000_09_006

Advertisement

loading

This manual is also suitable for:

Bs-468