Download Print this page

Olimpia electronics BS-465 Manual page 2

Pstn telephone dialer card for bs-468 panels

Advertisement

Figure 3 : "Connecting the telephone line".
CAPABILITIES
It can be set to send calls upon all events or
to selected events (i.e alarm, fault e.t.c) or in
combination of events (i.e. During an alarm
and fault). The programming can be done via
a BS-466 keyboard or computer.
There is the capability to test the availability
of the telephone line. This selection must be
disabled if the telephone line is used by
others telephone devices because it will
issue telephone line faults.
INCOMING CALLS
Regarding calls toward the PSTN module it is
required to enter one of the 2 codes (user or
technician) in order to retrieve the status of
the system. If an action is required (system
arming) e.t.c) then an additional code is also
required. When a call is placed to the GSM
and the GSM module picks up the line is will
issue one beep. After the beep is heard we
must enter the user or technician code using
our handset keyboard. If the code is wrong
t h e n 3 b e e p s a r e h e a r d a n d t h e l i n e i s
terminated. If the code is correct then the
system status message is replayed 4 times.
When the messages finish, a beep is heard
and the GSM waits for another code entry.
N o w w e c a n e n t e r t h e u s e r c o d e , t h e
technician code or one of the 50 general
purpose codes.
If the code is wrong then 3
beeps are heard and the line is terminated. If
the code is correct then the action(depending
on the code) is executed, 2 beeps are heard
and the new system status message will be
replayed 4 times after which the line will be
terminated.
OUTGOING CALLS
During an outgoing call, when the call is
Page 2 from 4
answered there is a beep sound and the
message concerning the state of the system
is played for 4 times.
If, for example the system is disarmed and
there is a fault then the message "FAULT,
D I S A R M E D " w i l l b e h e a r d f o r 4 t i m e s
whereas if there is an alarm and the system is
armed the message "ALARM, ARMED" will be
heard for 4 times. At the end of the message a
beep will be heard and after 5 seconds the
line will be closed. If during the message
period
any key apart from the "#" key is
pressed, on the receiving telephone, then 3
beeps are heard and the line is closed without
any other action. If the "#" key is pressed then
2 beeps are heard, the line is closed and the
PSTN dialer does not dial any other numbers
s i n c e o n e n u m b e r h a s a l r e a d y b e e n
informed. This is done to prevent disturbing
the other numbers.
ALARM RECEIVING CENTER (Contact ID)
The BS-465 can communicate with an alarm
receiving center (ARC). The communication
protocol is Contact ID (CID). Via the CID the
ARC is informed for every event that takes
place on the panel.
To communicate with the ARC, the technician
must enter 2 elements:
1) The telephone of the ARC center.
2) The panel ID.
Please note that the panel ID is unique for
each installation.
These elements are provided by the ARC
support company.
These elements are entered with the help of
the BS-466 keyboard.
Specifically on BS-466 keypad we have to
enter the technical menu, next the PSTN
m e n u
a n d
f i n a l l y
RECEIVING CENTER. In the picure below we
can see all the available oprions.
SIGNALS RECEIVING CENTER
STATE SRC
TELEPHONE SRC
ID PANEL, 0-9 & B-F
NOTIFY INCIDENTS
COMMUNICATION CHECK
COMMUNICATION TEST
STATE SRC
In that option we can activate/deactivate
s e n d i n g s i g n a l s t o t h e S R C ( S i g n a l s
Receiving Center).
c h o o s e
S I G N A L S
921465000_09_006

Advertisement

loading

This manual is also suitable for:

Bs-468