Download Print this page

Advertisement

Quick Links

BIONOMADIX SERIES
The BioNomadix system is a wireless, multi-channel physiological recording
platform. Its untethered design allows for nearly unlimited freedom of movement
and unsurpassed comfort, enabling subjects to easily relax into their protocol.
There are twelve different BioNomadix modules sets, each consisting of a
matched transmitter and receiver specifically optimized for desired physiological
signals. Multiple BioNomadix module sets (typically eight maximum) can be used
to create a customized BioNomadix system.
Each BioNomadix module set is capable of recording of two independent channels, with the exception of the
Accelerometer module, which records three channels.
BIONOMADIX TRANSMITTER AND RECEIVER SETS
BN-ACCL3 BioNomadix Accelerometer
BN-ECG2
BioNomadix 2-Channel ECG
BN-EEG2
BioNomadix 2-Channel EEG
BN- EGG2
BioNomadix 2-Channel EGG
BN- EMG2 BioNomadix 2-Channel EMG
BN- PPGED BioNomadix PPG and EDA
BN-GONIO BioNomadix 2-Channel Goniometry
BioNomadix
BN-GYRO-75
BIONOMADIX TRANSMITTER ONLY
BN-ACCL3-T
Accelerometer
BN-ECG2-T
2-Channel ECG
BN-EEG2-T
2-Channel EEG
BN- EGG2-T
2-Channel EGG
BN- EMG2-T
2-Channel EMG
BN- PPGED-T PPG and EDA
BN-GONIO-T Goniometry
Click to view a
BioNomadix System
BIONOMADIX LOGGER (BN-LOGGER)
BioNomadix Loggers wirelessly record physiological data as subjects freely and naturally live their lives—record
from up to three dual-channel wearable BioNomadix
BioNomadix Logger with GPS for a correlation between physiological and location data.
Use as a stand-alone system with AcqKnowledge or combine with BioNomadix Receivers and a computer
running AcqKnowledge:
NOTE: BioNomadix Logger requires AcqKnowledge software version 4.4.1 or higher.
PRODUCT SHEET
and
BN-GYRO-300
Angular Rate Sensors are
Diagram.
Get the real-world data your application demands!
Sync Transmitters to the Logger mode for remote data logging.
Combine Transmitters with BioNomadix wireless Receivers to
operate in the lab for real-time telemetry.
The compact Logger device provides a color display for visual
feedback, speaker for auditory feedback, vibration for haptic feedback,
voice journal for participant comments, event markers, and alarms.
Includes micro-USB to USB cable for charging/data transfer, AC
Charger and belt case.
*
Existing BioNomadix devices require a firmware upgrade to be
compatible with Loggers—see BN-TX-UPG online for details.
BIOPAC Hardware |
BioNomadix Series
BN-DYNEMG BioNomadix Dynamometry and EMG
BN- EOG2 BioNomadix 2-Channel EOG
BN-NICO
BioNomadix Cardiac Output
BN-RSP2 BioNomadix 2-Channel Respiration
BN-RSPEC BioNomadix RSP and ECG
BN-SKT2
BioNomadix 2-Channel Skin Temp
BN-STRIKE BioNomadix 2-Channel Heel/Toe Strike
BN-DYNEMG-T Dynamometry and EMG
BN- EOG2-T
BN-NICO-T
BN-RSP2-T
BN-RSPEC-T
BN-SKT2-T
BN-STRIKE-T
Transmitters*
plus a built-in accelerometer. Sync the
| Page 1 - 26
info@biopac.com
support@biopac.com
www.biopac.com
discontinued
items.
2-Channel EOG
Cardiac Output
2-Channel Respiration
RSP and ECG
2-Channel Skin Temp
2-Channel Heel/Toe Strike
Updated: 8.18.2020

Advertisement

loading
Need help?

Need help?

Do you have a question about the BioNomadix Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BIOPAC Systems BioNomadix Series

  • Page 1 PRODUCT SHEET support@biopac.com www.biopac.com BIONOMADIX SERIES The BioNomadix system is a wireless, multi-channel physiological recording platform. Its untethered design allows for nearly unlimited freedom of movement and unsurpassed comfort, enabling subjects to easily relax into their protocol. There are twelve different BioNomadix modules sets, each consisting of a matched transmitter and receiver specifically optimized for desired physiological signals.
  • Page 2 BN-LOG-CHRG for Loggers – full charge lasts 24 of operation with 30 days stand-by, full charge in approximately 12 hours. Both chargers provide a lifespan of 500 charge/discharge cycles—or 35,000 hours! BIOPAC Hardware | BioNomadix Series | Page 2 - 26 Updated: 8.18.2020...
  • Page 3 45.7 cm (18”) 45.7 cm (18”) 51.4 cm (20.25”) Back: Hip 61 cm (24”) 62.2 cm (24.5”) 64.8 cm (25.5”) 67.9 cm (26.75”) 71.1 cm (28”) Back: Length BIOPAC Hardware | BioNomadix Series | Page 3 - 26 Updated: 8.18.2020...
  • Page 4 BN-BIOSHIRTM3XL 111-117 cm (43.7-46.0”) BN-BIOSHIRTF2XL 85-89 cm (33.5-35.0”) BN-BIOSHIRTM4XL 118-124 cm (46.4-48.8”) BN-BIOSHIRTF3XL 89-93 cm (35.0-36.6”) BN-BIOSHIRTF4XL 93-97 cm (36.6-38.1”) Care Instructions: Wash separately, line dry, no fabric softener BIOPAC Hardware | BioNomadix Series | Page 4 - 26 Updated: 8.18.2020...
  • Page 5: Setup Overview

    Status light will turn green when communicating with transmitter. As with standard BIOPAC hardware, additional modules can be attached to the receiver. • Set desired channel options on the Receiver module. BIOPAC Hardware | BioNomadix Series | Page 5 - 26 Updated: 8.18.2020...
  • Page 6: Transmitter Battery Life

    If the paired signal is interrupted due to electrical interference or a subject wandering out of range, the most recently-acquired data point will be retained, with normal acquisition continuing once communication is reestablished. See also: BioNomadix Operational Range and Transmission Characteristics. BIOPAC Hardware | BioNomadix Series | Page 6 - 26 Updated: 8.18.2020...
  • Page 7 (±0.5 ms rms), the BN-EMG2 module is not recommended for applications such as Nerve Conduction Velocity or any physiological signal where equivalently small timing differences are being measured. For these types of studies, BIOPAC recommends the wired EMG100C amplifier. BIOPAC Hardware | BioNomadix Series | Page 7 - 26 Updated: 8.18.2020...
  • Page 8 Adapters can also be used with existing BIOPAC or 3rd-party goniometers and torsiometers to make them compatible with the BioNomadix wireless transmitter. These adapters are required if not using BioNomadix Transducers. BIOPAC Hardware | BioNomadix Series | Page 8 - 26 Updated: 8.18.2020...
  • Page 9 CH A: BN-PULSE-XDCR or BN- 2 x BN-EL50-LEAD4 PULSEEAR-XDR (or 2 x BN-EL50-LEAD2) CH A: BN-CLENCH-XDCR CH B: BN-ELxx-LEAD3 CH B: BN-EDA-LEAD2 or BN-EDA25- CH B: BN-ELxx-LEAD3 LEAD2 BIOPAC Hardware | BioNomadix Series | Page 9 - 26 Updated: 8.18.2020...
  • Page 10 A battery charger is included with each module pair. See BN-CHRG for charge time and recharge cycle details. Compliance: FCC, , IC, - FCC Part 15 B - FCC ID: receiver: ZWIBNXR1, transmitter ZWIBNXT1 IC: receiver: 9901A-BNXR1, transmitter: 9901A-BNXT1 BIOPAC Hardware | BioNomadix Series | Page 10 - 26 Updated: 8.18.2020...
  • Page 11 2 (red and white, BN-ADAPT-2) or 3 (red, white and black, BN-ADAPT-3) Electrode clips: 2 (BN-ADAPT-2) or 3 (BN-ADAPT-3) Length: 10 cm Interface: Use these adapters to connect 1.5 mm Touchproof electrodes to a BioNomadix transmitter. BIOPAC Hardware | BioNomadix Series | Page 11 - 26 Updated: 8.18.2020...
  • Page 12 Mount a platform to the underside of the table and rest the receiver with MP160/150 on it. This situation places the receivers just one or two meters away from the transmitters attached to the subjects. BIOPAC Hardware | BioNomadix Series | Page 12 - 26 Updated: 8.18.2020...
  • Page 13 YES: use standard gas sterilization techniques [i.e., Ethylene Oxide (EtO)] Variable Resistance Output: 5 - 125 KOhm Cable: 30 cm Interface: BN-RSP2 CH A RSP or CHB RSP, BN-RSPEC CHA RSP, or Smart Amplifier RSP100D BIOPAC Hardware | BioNomadix Series | Page 13 - 26 Updated: 8.18.2020...
  • Page 14 NO (Not designed for immersion) Cable: 30 cm Dimensions: 1.7 mm (diameter) x 5 mm (long) Interface: BN-SKT2 only: CH A SKT and/or CH B SKT, or Smart Amplifier SKT100D BIOPAC Hardware | BioNomadix Series | Page 14 - 26 Updated: 8.18.2020...
  • Page 15 PRODUCT SHEET support@biopac.com www.biopac.com Goniometer & Torsiometer Transducers BN-GON-XDCR, BN-TOR-XDCR, BN-GON-F-XDCR Use with BN-GONIO Goniometry Module. BIOPAC Hardware | BioNomadix Series | Page 15 - 26 Updated: 8.18.2020...
  • Page 16 1 x chest harness (holds cap in place) 1 x liquid soap (to wash cap after use) WHITE TIP WIRE COLOR RED TIP Brown Orange Yellow Green Blue Violet Gray White Black BIOPAC Hardware | BioNomadix Series | Page 16 - 26 Updated: 8.18.2020...
  • Page 17 For extremely long-term disuse, transmitter should be charged once a month, then disconnected between charge cycles. BIOPAC Hardware | BioNomadix Series | Page 17 - 26 Updated: 8.18.2020...
  • Page 18: Industry Canada Information

    (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. CLASS A ITE この装置は、クラスA情報技術装置です。この装置を家庭環境で使用すると 電波妨害を引き起こすことがあります。この場合には使用者が適切な対策を 講ずるよう要求されることがあります。VCCI-A BIOPAC Hardware | BioNomadix Series | Page 18 - 26 Updated: 8.18.2020...
  • Page 19 Transmitter/Receiver set. The total gain of the Transmitter/Receiver set is 10,000. The measured output voltage from the Receiver should be 1 mV p-p * 10,000 or 10 V p-p. The maximum input signal is 2 mV p-p. BIOPAC Hardware | BioNomadix Series | Page 19 - 26 Updated: 8.18.2020...
  • Page 20 Transmitter/Receiver set is 13 to 51 degrees C. Using the specified temperature probe: 13 degrees provides a - 10 V output and 51 degrees provides a +10 V output. BIOPAC Hardware | BioNomadix Series | Page 20 - 26 Updated: 8.18.2020...
  • Page 21 4. Use pencil to outline flattened portion of bulb on table, use ruler to measure the flattened area outline from side to side, and record this value as area "A" 5. Press CAL 2 - enter X/A kg/unit area BIOPAC Hardware | BioNomadix Series | Page 21 - 26 Updated: 8.18.2020...
  • Page 22 5. Click “Yes” to the channel scaling modification prompt. 6. Set desired Scaling as shown in the following table and click OK: ±16 G Range ±8 G Range ±4 G Range ±2 G Range BIOPAC Hardware | BioNomadix Series | Page 22 - 26 Updated: 8.18.2020...
  • Page 23 Filter Option Switch Number Filter Option CH A CH B Low Pass Low Pass 1 Hz HP 10 Hz LP DOWN DOWN Disabled DOWN 1 Hz LP UP** BIOPAC Hardware | BioNomadix Series | Page 23 - 26 Updated: 8.18.2020...
  • Page 24 10 Hz LP Envelope detection mode EMG CH B 100 Hz LP DOWN EMG signal output DOWN* HP N/A for DYN High Pass 10 Hz HP 1.0 Hz HP DOWN BIOPAC Hardware | BioNomadix Series | Page 24 - 26 Updated: 8.18.2020...
  • Page 25 DOWN DOWN Alpha – Alternative Signal DOWN Beta – Alternative Signal EMG2-R BioNomadix Receiver Signal Output EMG – Factory Preset DOWN Integrated RMS Alternative Signal (Envelope Detection Mode) BIOPAC Hardware | BioNomadix Series | Page 25 - 26 Updated: 8.18.2020...
  • Page 26 3 Hz LP 3 Hz LP 100 Hz LP DOWN* 100 Hz LP DOWN* Low Pass 10 Hz LP 10 Hz LP 100 Hz LP DOWN 100 Hz LP DOWN BIOPAC Hardware | BioNomadix Series | Page 26 - 26 Updated: 8.18.2020...