  • Page 1 Safety Vent AIR – Instruc�on Manual...
  • Page 2 VisionLINE Safety Vent AIR Flue System Thank you for purchasing a VisionLINE AIR flue system for you slow combustion fireplace. Please read this manual carefully to ensure the correct installation of the flue system. VisionLINE Safety Vent AIR has been tested to Appendix F of Joint Australian & New Zealand...
  • Page 3 VisionLINE insulated air intake flue system 150mm (6”) insulated stainless pipe Please read these assembly instructions carefully prior to installation. To be installed by a qualified installer only, please check local requirements for qualification requirements. Incorrect installation is a fire risk and will result in a loss of warranty. Distance required to combustible materials The minimum distance of clearance to a combustible material for the VisionLINE Safety Vent Air pipe is 50mm.
  • Page 4 Fitment of VisionLINE Safety Vent AIR pipe Once the flue bracing bracket is in place, fit a section of VisionLINE AIR pipe in place ensuring that enough pipe has passed down through the ceiling to meet the clearance requirements before using the conversion piece to convert to VL double wall stove pipe (see FIG 3) FIG 3.
  • Page 5 (See FIG 3) Connec�ng VisionLINE AIR pipe Once the flue brace bracket is secure and in place, you can now start to a�ach further lengths of pipe to continue and penetrate the roof.
  • Page 6 Fi�ng double wall stove pipe Once the VisionLINE Safety Vent AIR pipe is in place, you can now fit the double wall stove pipe inside the house to connect to your fireplace. Fit the Safety Vent AIR to stove pipe adaptor to the protruding AIR flue pipe.
  • Page 7 Use of bends 45o Bends can be used on this flue system. Either the stove pipe flue or the VisionLINE safety vent flue can be offset. A maximum of two (2) sets of 45o elbows can be used. A maximum of 1800mm in total can be run at a 45o angle.
  • Page 8 Standard flue components Code Description VF-3-60-001 AIR FLUE RAIN CAP VF-3-60-203 AIR FLUE SAFETY VENT 1000MM VF-3-60-202 AIR FLUE SAFETY VENT 500MM VF-3-60-201 AIR FLUE SAFETY VENT 250MM VF-3-60-245 AIR FLUE SAFETY VENT 45 ELBOW AIR FLUE ELBOW SUPPORT BRACKET VF-3-60-246 VF-3-60-003 AIR FLUE SUPPORT 2...
  • Page 9 Component specs Below the ceiling Stove pipe elbow T-Section Flush spigot adapter VF-3-60-145 VF-3-60-090 VF-3-60-092 To be used when Ø193 the fireplace has 45° a hidden spigot 193 mm 65 mm C X 2 148 mm Stove pipe Adjustable Stove pipe Ø193 Ø193 Part number...