Download Print this page

Grohe Talia 19 263 Manual page 5

Hide thumbs Also See for Talia 19 263:

Advertisement

Installation
Finish plaster wall and tile up to the fitting template. When
doing so, seal wall openings against water splashes.
• In the case of tiles laid in mortar, pointing must be bevelled
outwards.
• In the case of prefabricated walls, seal with elastic sealing
compounds.
1. Remove the two screws (A1) from the fitting template (A),
then remove the template, see fig. [1].
2. Unscrew adjusting nut (B) and detach stop ring (C),
discard both parts.
3. Fit stop ring (D) with green adjusting nut (D1) provided
with marking (D2) facing upwards, see fig. [2].
4. Fit clamp (E).
5. Screw in green adjusting nut (D1).
6. Install the compensation ring (F) if using rough-in
valve 34 122, the ring is not needed for rough-in
valve 34 124, see fig. [3].
7. Push sleeve (G) with the mark (G1) upward onto the
mixer shank, make sure that the marking point (D2) snaps
into the sleeve (G).
8. Grease seal (H1) with the grease provided, see fig. [4].
9. Slide the escutcheon (H) over the sleeve (G).
10. Slide snap inserts (I) over screws (J) and secure
escutcheon (H) to the valve.
Do not use excessive force to tighten the screws.
11. Cover the srews with cover caps (K).
12. For assembly of the thermostat handle, see chapter
"Adjustment".
If thermostat is installed too deep, the fitting depth
can be increased by 1 1/8" (27.5mm) with extension set , Prod.
no. 47 358, see page 2.
Adjustment
Temperature setting
• Before the mixer is put into service, if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the thermostat handle.
• After any maintenance operation on the thermostatic
cartridge.
1. Open shut off valve (L) and measure the temperature of the
water emerging with a thermometer, see fig. [5].
2. Turn the green regulator nut (D1) clockwise - counter-
clockwise with a screwdriver until the water emerging has
reached a temperature of 100 °F.
3. Fit the thermostat handle (M) so that the 100 °F mark on
the thermostat handle lines up with the mark (G1) on the
sleeve (G), see fig. [6].
4. Insert fixing ring (N).
5. Push on cap (O) and mount lever (P) by screwing on the
sleeve (P1).
Reversed union (cold on left - hot on right).
Replace thermostatic cartridge (47 050) or (47 582),
see replacement parts page 2, ref. No.: 47 282 (1/2")
and 47 379 (3/4").
English
Temperature limitation
When in proper calibration, the temperature range is limited
to 110 °F. There is a safety check at 100 °F.
If a higher temperature is desired, one can exceed 100 °F by
overriding the safety check.
Prevention of frost damage
When the domestic water system is drained, the thermostat
mixers must be drained separately, since check valves are
installed in the hot and cold water connections.
The complete thermostat assembly and check valves must be
unscrewed and removed.
Maintenance
Inspect and clean all parts, replace if necessary and grease
with special valve grease (Prod. no. 18 012).
I. Thermostatic cartridge
1. Turn thermostat handle (M) to the 100 °F safety check,
see fig. [6].
2. Unscrew sleeve (P1) and pull off lever (P).
3. Remove cap (O).
4. Take out fixing ring (N).
5. Pull off thermostat handle (M).
6. Pull sleeve (G) from the mixer shank by pressing
down the tongue (D3), see fig. [7].
7. Extract clamp (E).
8. Pull stop ring (D) until resistance is encountered
(approximately 3/8" [10mm]), see fig. [8].
9. Unscrew stop ring (D) complete with regulator
nut (D1).
10. Remove escutcheon (H), see fig. [4] and installation,
points 9 - 11, in reverse order.
11. Close both service stops (R).
12. Unscrew thermostatic cartridge (47 050, 47 582)
with 24mm open-ended wrench, see page 2.
Readjustment is necessary after every maintenance operation
on the thermostatic cartridge (see Adjustment).
II. Check valve
1. Proceed as for maintenance of thermostatic cartridge,
points 1 - 5, 10 and 11.
2. Unscrew check valve (14 116, 12 510) with 17mm
socket wrench or 10mm hex key, see page 2.
Reassembly should be carried out in reverse order.
Observe the correct mounting position!
Replacement parts, see page 2 (* = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement
4

Advertisement

loading