TABLE OF CONTENTS PREFACE ........................... 2 INTRODUCTION ......................2 PRODUCT DESCRIPTION ..................... 3 SAFETY ........................3 INSTALLATION ......................4 USE ........................... 7 MAINTENANCE ......................7 TROUBLESHOOTING ....................8 SPARE PARTS ......................8 DISPOSAL ........................8 CE DECLARATION ........................8 EN | ORIGINAL INSTRUCTION All rights reserved.
- type ATEX: approved for use in explosive environments PREFACE Zone 22; marking EX II 3D (for hanging mounting only) Using this manual Options and accessories This manual is intended to be used as a work of reference for Arm-fan adapter professional, well trained and authorised users to be able to for connection of the KUA-200 with a fan safely install, use, maintain and repair the product mentioned...
regulations. Observe all applicable safety PRODUCT DESCRIPTION instructions and regulations. Components User manual The product consists of the following main components and - Everyone working on or with the product, must be familiar elements: with the contents of this manual and must strictly observe the instructions therein.
- Stay alert and keep your attention to your work. Do not • Safety features which have been removed for service, install the product when you are under the influence of maintenance or repairs, must be put back immediately drugs, alcohol or medicine. after finishing these jobs and it must be checked that they still function properly.
Page 6
- a steel profile (e.g. H-profile), using four threaded rods M10. For this purpose two square tubes (30x30x3 mm) need to be mounted to prevent bending. WARNING! Before you install the product, make sure that the wall or mounting structure is strong enough. Refer to paragraph 1.5 for the weight of the product.
Page 7
4.5.6 Hose Fig. 4.6 • Slide the hose (C) over the aluminium collar (ref. Fig. 4.3D). • Fasten the hose with the hose clamp (B). • Slide the rubber collar (A) over the hose clamp to make the connection airtight. Fig.
MAINTENANCE Periodic maintenance Personal protective equipment (PPE) During use, use PPE to avoid injury. This The product has been designed to function without also applies for persons who enter the work problems for a long time with a minimum of area.
Middle hinge CE DECLARATION CE declaration of conformity for machinery We, Plymovent Manufacturing B.V., Koraalstraat 9, 1812 RK Alkmaar, Netherlands, herewith declare, on our own responsibility, that the products: - KUA-200/3H ATEX - KUA-200/4H ATEX...
Page 10
ANNEX Fig. I Working reach KUA-200/3 KUA-200/4 inch inch 1150 45.3 1450 57.1 1450 57.1 1620 63.8 3440 135.4 4130 162.6 Fig. II Pressure drop KUA-200/3 KUA-200/4 1200 1100 1000 1100 1300 1500 1700 m³/h 0000113485/011020/B KUA-200...
Need help?
Do you have a question about the KUA-200/3H and is the answer not in the manual?
Questions and answers