Download Print this page

Grohe Geneva 20 801 Quick Start Manual page 4

Hide thumbs Also See for Geneva 20 801:

Advertisement

959121.book : i95912us.fm Seite 1 Donnerstag, Oktober 25, 2001 3:37 PM
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit with pressure reducing valves
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
Note
Major pressure differences between cold and hot water supply
should be avoided.
Installation
See dimensional drawing on fold-out page I.
Flush pipes thoroughly!
Side valves
• Valve marked with "L" (left close) on the top edge of the
cartridge (A) with blue tape should be mounted on the right
(cold water) side.
• Valve marked with "R" (right close) on the top edge of the
cartridge (A) with red tape should be mounted on the left
(hot water) side.
1. Screw the mounting set (B) to the bottom of the thread of the
side valve (C), see fold-out page III, fig. [1].
Make sure that the rubber washer (B1) is on the top of the
fiber washer (B2).
2. Insert the side valve (C) through the basin hole from below.
3. Place the escutcheon O-ring (D1) on the basin and screw
down the escutcheon (D) until it stops.
4. Screw the cap (E) down to the escutcheon (D).
5. Secure the handle (F) or lever (G) to the stem of the
ceramic cartridge (A).
It is recommended that the lever handle (G) be installed so
they point away from the spout when in the off position.
If the gap between the handle and the cap is excessive,
back off the cap (E) and the escutcheon (D) to minimize the
gap.
6. Tighten the mounting set (B) from below to secure the valve.
1
English
Spout
1. Place the O-ring (I) and the escutcheon (H1) on the basin,
2. Insert the spout (H) through the escutcheon (H1) and basin.
3. Place the gasket (J) against the bottom of the basin and
4. Connect flexible hoses (L) from spout connection tee to the
9.5 L/min or 2.5 gpm/80 psi
Mount lift rod and pop-up drain
8.3 L/min or 2.2 gpm/60 psi
1. Screw the knob (M1) to the upper lift rod, see fig. [4].
2. Insert the lift rod (M) through the spout and screw on the
7.25 psi
14.5 - 72.5 psi
3. Fit pop-up drain (28 957), see fold-out page II.
145 psi
232 psi
Connect wideset
176 °F
Connect the side valves to the water supply. Insure the
cold - Right hand
supplied washers are used for all connections.
hot - Left hand
The hot water supply should be connected on the left side
valve (marked red) and the cold water supply to the right valve
(marked blue).
Open cold and hot water supply and check connections
for leakage.
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease (order no. 18 012).
Shut off cold and hot water supply.
I. Ceramic cartridge, see fold-out page II.
- Remove handle (45 776, 45 790) and cap.
- Unscrew the ceramic cartridge (45 882 - right close,
II. Flow regulator, see fold-out page II.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
see fig. [2].
fasten with the flange (K) and nut (K1).
Tighten hexagon nut with a 13mm socket wrench, see
fig. [3].
side valves, see figs. [4] and [5].
lower lift rod (N).
The connector is at the lower lift rod (N).
Ensure that flange of pop-up drain is sealed.
45 883 - left close) using a 17mm (11/16") wrench.
Unscrew and clean flow regulator (13 931).

Advertisement

loading