Mounting and operation manual Contents Make the mains connection About this manual Mounting with mains plug Content and purpose 5.2 Mounting with fixed connection Target group Limitations of liability Commissioning Symbols used Requirements Safety 6.2 Carry out a learning cycle Safety instructions 6.3 Set speed and hold-open time...
The acceptance inspection must only be carried out by Safety qualified technical personnel authorized for this by dormakaba. Safety instructions The operation of the CS 80 MAGNEO may be carried out by any person who is mentally and physically WARNING capable of doing so. Limitations of liability...
20 kg to 80 kg. The The CS 80 MAGNEO is developed according to the CS 80 MAGNEO can be used in a 1- or 2-leaf bi- latest safety standards and certified by a TÜV type parting.
Functions of the door in automatic WC function active mode DIP 9 WC function inactive The CS 80 MAGNEO is delivered in automatic mode. Depending on the trigger, the door is opened in locking DIP 8 different ways. no locking increased end thrust 3.6.1...
3.13 Full power mode the door quickly in an emergency. dormakaba recommends that the barrier-free WC be additionally In full power mode, the forces are also limited. Due to...
Mounting 3.15 Standards, laws, guidelines and regulations Safety during mounting The CS 80 MAGNEO is a low energy product according to DIN 18650/EN 16005. The DIN 18650/ EN 16005 calls for the basic protection of an WARNING automatic door’s area of movement through the use of safety sensors, among other things.
Mounting and operation manual Mounting Mains connection 4.6.1.1 Mark vertical reference lines Mark the center of the passage on the wall. 4.5.1 Mounting with mains plug The earthing contact socket must be mounted within 2200 mm and be accessible by hand after mounting.
Page 9
Mounting and operation manual Mounting 4.6.1.2 Mark horizontal reference lines Reference line Determine the highest point of the floor in the leaves’ area of movement. TIPS AND RECOMMENDATIONS Use leveling device. Closed position Opening width Excess max. Excess max.
Page 10
Mounting and operation manual Mounting 4.6.2.1 Mounting without lining plate 4.6.2.2 Mounting with lining plate Position the mounting bracket with the triangle’s Position the lining plate on the reference line. lower point on the center line. Reference line 2. Align the mounting bracket horizontally.
Page 11
Mounting and operation manual Mounting 4.6.3 Mount the drive 2. Align the door leaf with a maximum distance of 8 mm parallel to the wall. Stick 3 pieces of felt evenly distributed on the When aligning, make sure the door leaf can be mounting bracket.
Page 12
Mounting and operation manual Mounting 4.6.5 Set end stops Attach the dormakaba logo in the drill holes. Depending on the structural conditions, shorten or break off the end caps at the predetermined max. area of max. dimension Y breaking points.
Mounting and operation manual Mounting Mounting in the wall A = at least L + 120 mm Drive length [L] min. 50 mm min. 70 mm Lintel’s bottom edge Closed position Fig. 25 Overview of mounting in the wall TIPS AND RECOMMENDATIONS Door leaf version...
Page 14
Mounting and operation manual Mounting 3. Determine the highest point of the floor in the 3. Mark another line at a distance of 43 mm. leaves’ area of movement with a leveling device. Fig. 30 Screw the fixing lug on Fig. 27...
Page 15
Mounting and operation manual Mounting 4.7.3 Mount the door leaf 8. Mark the fixing holes through the drive’s holes. Move the carriage to access all 4 holes if necessary. ATTENTION Risk of damage to the glass components by contact with hard materials (e.g. glass, metal, concrete).
Page 16
Mounting and operation manual Mounting 6. Adjust the height of the door leaf with the 5. Loosen the screws on the end stop on the other adjusting nuts so that the door leaf hangs side. horizontally and the distance to the ground is between 6 and 8 mm.
Mounting and operation manual Make the mains connection Make the mains connection Warning! Disconnect the power supply before mounting! Warning! Turn the power switch to OFF! 3. Mark the end stop’s position on the connection side. Fig. 43 Pull out the connection socket Mounting with mains plug Pull out the internal connection socket.
Mounting and operation manual Commissioning Commissioning 10. Close the cover of the control housing. The visual feedback takes place via the LED operating display. Requirements • The CS 80 MAGNEO is completely mounted. • The door can easily be moved over the entire area of movement.
Mounting and operation manual Commissioning Set speed and hold-open time ATTENTION Risk of damage to the potentiometer. The potentiometers can be damaged by excessive forces. • Please only use the enclosed red screwdriver for settings! Set the speed on the speed potentiometer (Fig. 49/1).
Mounting and operation manual Connect optional accessories Connect optional accessories Connect accessories Carefully open the cover from the control housing Warning! with the tip of a flat-bladed screwdriver. Turn the power switch to OFF! 2. Strip the supply leads of external devices (sensors, switches, etc.).
Page 21
Mounting and operation manual Connect optional accessories 7.2.1 Connecting the optional closing edge protection Connect the closing edge protection according to the wiring diagram or connection plan. Prosecure Opti Scan 1 on the main closing edge Prosecure Opti Scan 1 on the secondary closing edge...
Page 22
Mounting and operation manual Connect optional accessories 7.2.2 Connect the optional WC control Connect the WC control according to the wiring diagram. WC public area (Fig. 56), WC private area (Fig. 57). The connection diagrams are exemplary. Indoor area Outdoor area Fig. 56...
Mounting and operation manual Commissioning Commissioning 8.2.3.1 For private areas The visual feedback takes place via the operating To activate the function, set the DIP switch 8 to display (LED). the OFF position and set the DIP switch 9 to the ON position.
Mounting and operation manual Commissioning Carry out a learning cycle DIN 18650/EN 16005 The values saved during the learning cycle are If the door is to be operated according to DIN 18650/ overwritten on a new learning cycle. EN 16005, the following requirements apply: •...
• Please only use the enclosed red screwdriver for settings! Door behavior in automatic mode The CS 80 MAGNEO is delivered in automatic mode. Depending on the devices installed, the door is opened Set the speed on the speed potentiometer in different ways.
Mounting and operation manual Maintenance and care Using WC in a Private Area 9.6.3 Leaving the WC After pressing the locking button on the inside, the 9.5.1 Access to the WC door is opened. The Engaged indicator inside and After pushing the activation button on the outside, outside changes from red to green.
We want to win you over too – get a non-binding and free offer for a maintenance contract. Further information on this and many other topics of the dormakaba service can be found on our homepage at www.dormakaba.com 0 800 524 0246...
Mounting and operation manual Troubleshooting Troubleshooting Malfunction Possible causes Remedy Door is switched on No power supply available Check power supply Door is not Power cable connection not firmly Plug in the power cable connection firmly responding plugged in...
Page 29
Mounting and operation manual Troubleshooting Malfunction Possible causes Remedy Opening width set incorrectly Reset opening width (end stops) Carry out a learning cycle Red LED flashes Door’s area of movement is blocked Clear the area of movement cyclically 6 times...
Disassembly is carried out in the reverse order of mounting and must be carried out by qualified hereby declares that the partly completed machine personnel. CS 80 MAGNEO, CS 80 MAGNEO SYNC complies with the following essential requirements of DANGER the Machinery Directive (2006/42/EC) - Annex I,...
Need help?
Do you have a question about the CS 80 MAGNEO and is the answer not in the manual?
Questions and answers