E T C S e t u p G u i d e
Co nnector Pinouts
DMX 512
connector pinout
Pin
Use
1
Common (shield)
2
Data -
3
Data +
4
no connection
5
no connection
O p e r a t i o n O v e r v i e w
removable label
strip
1
Esc
Ch
Backlit indicators identify the operating status of the light server.
LEDs indicate which mode the unit is operating (server, backup, client) and the status of the operation
(master, backup sync or offline).
The "Server" LED will illuminate when the unit is configured as a server.
The "Backup" LED will illuminate when the unit is configured as backup.
The "Client" LED will illuminate when the unit is configured as a client.
The "Master" LED will illuminate when the unit is controlling the lighting system, and will blink
when the Backup is in control.
The "Sync" LED will illuminate when the unit is synchronized with a server and will blink when the
connection to the server has been lost.
The "Offline" LED is illuminated when the unit is running offline.
20 command keypad buttons are configured for single Congo commands.
The 20 command buttons are set to default button assignments for optimal operation. Press and hold
the [Shift] button to select the alternate function of any button (for example: [Shift] [1] to Escape).
USB port is provided for easy show loading to or from a USB storage device.
C on go L ig ht Se r ver S et up G u id e
Push
5
1
4
2
3
20
command
keypad buttons
2
3
Mod
4
Ins
5
Live
6
Frmt
+
@
Thru
All
Del
GoTo
Outp
Go
S1
1
2
S2
3
4
S3
5
6
S4
7
8
backlit
indicators
7
Tab
8
Brws
9
0
Macro
LdPly
Server
.
Mast
Pause
GoBa
C
Rec
Shift
Master
Page 3 of 3
Congo Light Server
Remote Trigger
connector pinout
8
9
Relay Out, Normally Closed
10
Relay Out, Normally Open
Relay Out, Common
11
12
Ground
13
Ground
14
+ 12Vdc
15
+ 12Vdc
USB
Backup
Client
Sync
Offline