Pastacooker error catalog

Error description / display
1
Error 1
Call up the PT 100 menu
Note the display
2
Machine heats up through unregulated
3
conventional machine heats through
unregulated
4
The machine only heats when the red
heating pulse switch is pressed
5
No indication on the display
6
Residual current switch / fuse blows out
7
Conventional machine, power switch
green does not ligh up
8
Lift motors only run halfway up/down
9
Lift motors are moving in the wrong
direction
10
No water supply
11
Machine leaking
How to fix
Check PT-1000 connection
If, ok, then measure the PT-1000
ohmic value
Check contactor
Check software version
Perform a CPU reset
Reset limiter button
Check thermostat
check contactor
Replace heating limit switch
De-energize the device
Electronics defective
The heater has a short circuit
Check wiring
burnt heater plug
Phase – Phase oder Phase-
0-wire short circuit
SSR/ Triac has short circuit
Press the limiter button or
replace.
Replace capacitor 33μF/ 270V
clean the lift motor
Capacitors 33μF/ 270V
double mounted.
Check cable connection of hoist
motor (phases reversed)
Check solenoid valve
Check PT-1000 seal
Check drain system
Check water supply
6
w w w.gastrofrit.ch
Remarks
OK = about 108 ohms / 20 ° C
NOK = 0 ohms or infinite
Contactor sticks, contactor has to
be checked and possibly replaced
Thermostat misadjusted and not
adjusted
Can`t always be replaced
must be bridged
Change control
Capacitor value cancels
corresponds to the value if no
capacitor is installed
Solenoid valve cold water up to
50ºC
Solenoid valve hot water up to
100ºC
© Switzerland Gastrofrit AG

Advertisement

Table of Contents
loading