Instruction Manual
PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE
INSTALLATION OR USE OF THIS PRODUCT. KEEP IT IN A SAFE
PLACE FOR FUTURE REFERENCE. FOLLOW ALL WARNINGS AND
INSTRUCTIONS MARKED ON THE PRODUCT.
CS10M-24 (Medical)
CS10S-24 (Standard)
CS Base
Models
CS10M-48 (Medical)
CS10S-48 (Standard)
The CS series power supply should be supplied only by a power source of the type indicated on its label. The unit should only be used with suitably
rated cables and appropriate IEC320 type connector where applicable, sourced by the end user, and in accordance with the requirements of Table 3B
of IEC60950-1 (latest edition) & Table G.5 of EN62368 (latest edition) If in doubt, contact Excelsys Applications Department for assistance. Double pole
/ neutral fusing is used. If the installation is not completely disconnected from power, parts may remain live even if one of the two main fuses has blown.
When securing the product, do not use screws which infringe the maximum penetration depth of 2mm for Base mounting and 2mm for Side mounting.
Customer fixings are provided on the base and side of the chassis. Maintain a 50mm minimum clearance all around the power supply to allow for
adequate natural convection cooling to take place.
PARTS OF THE UNIT WILL BECOME HOT DURING OPERATION; ALLOW TIME TO COOL BEFORE HANDLING.
AFTER DISCONNECTING THE AC SOURCE, ALLOW 4 MINUTES BEFORE DISASSEMBLY TO ALLOW CAPACITORS WITHIN THE UNIT TO
DISCHARGE.
INPUT SPECIFICATIONS
Input Voltage Range:
Input Frequency:
Earth Leakage Current:
INPUT FUSING
WARNING!
There are no serviceable parts in this product - Return to Excelsys for repair.
Model
Reference
CS10M/S-24
FS1
FS2
CS10M/S-48
FS1
FS2
OUTPUT SPECIFICATIONS
See Output table below, with more detail in Designers' Manual. Each Model may be adjusted over the
full voltage range shown in the table subject to not exceeding the maximum rated Voltage and Power
(1)
shown in the table
.
Model
Vmin (V)
Vnom (V)
CS10M/S-24
22
CS10M/S-48
44
Model – Auxiliary Output
Vnom (V)
CS10M/S-24 & 48
CS10M/S-24 & 48
SAFETY
The CS models when correctly installed in a limited access environment are designed to comply with
the following requirements:
CS10S: IEC62368-1
CS10M: ANSI/AAMI ES60601-1, CSA 22.2-60601-1, IEC60601-1 and EN60601-1
For current approval status, please contact Excelsys Sales. Equipment manufacturers must protect
service personnel against inadvertent contact with the output terminals.
The user should connect to the screw barrier terminal input connector version using wiring terminated
with grip sleeve insulated, fork/spade tongue terminals for stud Size 6 (M3.5).
For supply connections, use wiring materials suitable for at least 105°C
The power supply FG (Functional Ground) terminal of Terminal Block is connected to printed wiring
board trace directly; the Limited Short-Circuit Test in CSA C22.2 No. 0.4, Bonding of Electrical
Equipment not conducted due to building-in type component. The evaluation shall be considered in
end-product.
WARNING: Do not modify this equipment without authorization of the manufacturer
ENVIRONMENTAL PARAMETERS
The products are designed for the following parameters:
• Pollution Degree 2
• Installation Category 2
• Class I - Equipment achieves electric shock protection through basic insulation and protective earth
grounding.
• For use as part of another piece of equipment such that unit is accessible to service engineers only
Doc. No: 40124r00
24V/41.67A
1000W
24V/41.67A
1000W
48V/20.83A
1000W
48V/20.83A
1000W
100 to 240Volts AC
50-60Hz
300µA - Standard Options
150µA - Low Leakage Options
Fuse
Type
Voltage
Rating
10A
T
500VAC/400VDC
10A
T
500VAC/400VDC
10A
T
500VAC/400VDC
10A
T
500VAC/400VDC
Vmax (V)
Imax (A)
Power (W)
24
28
41.67
48
56
20.83
Imax (A)
Power (W)
5
4.8
24
12
2.0
24
CS10 Instruction Manual
CS Series products are designed for use within other equipment or enclosures,
which restricts access to AUTHORISED COMPETENT PERSONNEL ONLY. This
equipment is only intended for use in a restricted access area. The unit covers are
designed only to protect skilled personnel from hazards. They must not be used as
part of the external covers of any equipment where they may be accessible to
operators, since, under full load conditions, part or parts of the unit may reach
temperatures in excess of those considered safe for operator access. This
equipment is not suitable for use in locations where children are likely to be present.
ENVIRONMENTAL PARAMETERS (Continued)
Environmental Conditions for Normal Operations
• Altitude: -155 metres to +5000 metres from sea level
• Relative Humidity: 5% to 95% non-condensing
• Temperature Range: -25°C to +85°C
• Derate output power at 1.67% per °C above 40°C and up to 85°C
(NOTE: IEC input terminal option limits maximum operating temperature to 50°C)
• Derating of 15% across all line voltages applies when lid is used on product.
Size
Environmental Conditions for Transport & Storage
5.0 x 20mm
• Altitude: -155 metres to +15200 metres from sea level
5.0 x 20mm
• Relative Humidity: 5% to 95% non-condensing
5.0 x 20mm
• Temperature Range: -40°C to +85°C
5.0 x 20mm
APPROVAL LIMITATIONS
Use in North America
When this product is used on 180 to 253 Volts AC mains with dual Fuse, no neutral, connect one
live wire to L (live) terminal and the other live wire to N (neutral) terminal on the input connector.
The attachment plug shall be rated to a current not less than 125% of the rated current of the
equipment.
1000
1000
LEVELS OF INSULATION
Subject to the limitations above
Dielectric strength testing is carried out as follows:
• Primary mains circuits to chassis: 1500V AC
• Primary mains circuits to secondary: 4.8KV AC or 6788VDC.
• Secondary to chassis: 1850V AC.
EARTH TERMINAL IMPORTANT
The protective earth must be considered in the end system. The input terminal block guarantees
Functional Ground (FG)only on pin 2, the protective earth only provided by connecting directly to
chassis. The power supply is only a component of the system and therefore must not be relied
upon to provide protective earth for the end application. The IEC inlet input provides a protective
earth connection. For further information, please contact Excelsys Technologies.
HEALTH AND SAFETY AT WORK ACT (UK ONLY)
To protect service personnel and users and to comply with section 6 of the Health and Safety
Acts, a clearly visible label should be fitted warning that surfaces of these units may be hot and
must not be touched when the units are in operation.
RECEIPT AND UNPACKING
On receipt a unit should be unpacked carefully and checked for transit damage. If the unit is
damaged, do not apply power or install the unit. SEEK SPECIALIST ADVICE!
WARRANTY
Warranty conditions are contained in our standard terms and conditions. Contact your authorised
outlet for repair.
Excelsys Technologies Limited,
27 Eastgate Drive,
Eastgate Business Park,
Little Island, Cork, Ireland
HIGH VOLTAGE WARNING!
Dangerous voltages are present within
these power supplies. These products
should only be worked on by qualified
personnel.
Excelsys Technologies Ltd

Advertisement

loading

Summary of Contents for Advanced Energy Excelsys CS Series

  • Page 1 Excelsys Technologies Limited, 27 Eastgate Drive, Eastgate Business Park, Little Island, Cork, Ireland Instruction Manual PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE HIGH VOLTAGE WARNING! Dangerous voltages are present within INSTALLATION OR USE OF THIS PRODUCT. KEEP IT IN A SAFE these power supplies.
  • Page 2 Input Connector (J2 or J11): Barrier Terminal Block (J2): TE/Tyco: 2-1437667-5; Dinkle: DT-31-B01W-03 IEC Input Option (J11): Schurter GSP2.9103.13; Rong Feng 701W-G40111 Output Connector (J4 & J5): Barrier Terminal Block (J4 & J5), TE/Tyco 2-1437667-5; Dinkle: DT-31-B01W-03 Auxiliary Output Connector (J12): Lite-Trap™...
  • Page 3 Set Droop (J14): 2 Pin Header, Harwin: M22-2510205; Cvilux: CH11022VA00-NH Shorting Jumper:- Harwin: M22-1900005 PM Bus/Aux Voltage Setting (Pin11 & 12) J17): 12 Pin Header, Harwin: M22-252060; Molex: 87758-1216 Shorting Jumper for pins 11 & 12:- Harwin: M22-1900005 Input/Output/Signal Connector Details Input Output Output...
  • Page 4 CS10 – BARRIER CONNECTOR LID FITTED MECHANICAL SPECIFICATIONS Mounting Holes: 4 x M4 threaded PEMs on Base. Max Screw Penetration is 2mm from Base. 2 x M3 threaded PEMs on Each Side. Max Screw Penetration is 2mm from Side. Doc. No: 40124r00 CS10 Instruction Manual Excelsys Technologies Ltd...
  • Page 5 CS10 – BARRIER CONNECTOR NO LID FITTED MECHANICAL SPECIFICATIONS Mounting Holes: 4 x M4 threaded PEMs on Base. Max Screw Penetration is 2mm from Base. 2 x M3 threaded PEMs on Each Side. Max Screw Penetration is 2mm from Side. Doc.
  • Page 6: Mechanical Specifications

    CS10 – IEC CONNECTOR NO LID FITTED MECHANICAL SPECIFICATIONS Mounting Holes: 4 x M4 threaded PEMs on Base. Max Screw Penetration is 2mm from Base. 2 x M3 threaded PEMs on Each Side. Max Screw Penetration is 2mm from Side. Doc.
  • Page 7 CS10 – IEC CONNECTOR LID FITTED MECHANICAL SPECIFICATIONS Mounting Holes: 4 x M4 threaded PEMs on Base. Max Screw Penetration is 2mm from Base. 2 x M3 threaded PEMs on Each Side. Max Screw Penetration is 2mm from Side. Doc. No: 40124r00 CS10 Instruction Manual Excelsys Technologies Ltd...
  • Page 8: Part Numbering System

    CS Model Label Contains: Input Freq, Input Voltage, Fuse Rating, Max Power Rating, Serial Number, Maximum Line Current under rated conditions. Warning Symbol (Danger High Voltage) Warning Symbol (Caution Hot Surface) Model Configuration as defined by the diagram below this text. Notes: 1.