ABB MRP31.0 Manual page 14

Modbus rtu communication module, universal motor controller
Hide thumbs Also See for MRP31.0:

Advertisement

14
U N I V E R S A L M OTO R C O N T R O L L E R U M C 1 0 0 . 3 | M R P 3 1 . 0 M O D B U S T C P C O M M U N I C AT I O N M O D U L E M A N U A L
Access to the monitoring data of UMC100.3 acc. to the UMC100.3 manual section
A1 parameters and data structures on a Fieldbus
Register
Bit 7
Bit 15
Summary
Warning
0x0000
UMC100 DI5
Access to the command data of UMC100.3 acc. to the UMC100.3 manual section
A1 parameters and data structures on a Fieldbus
Register
Bit 7
Bit 15
Bit 23
Bit 31
-
0x0100
UMC100 DO2
VI15x
DO0
0x0101
-
Word oriented access to diagnosis data of UMC100.3 acc. to the UMC100.3 manual section
A1 Parameters and Data Structures on a Fieldbus
Register
Bit 7
Bit 15
Checkback
missing
0x2000
Actuator
problem
Trip/Warning
from
Aux-Fault
function
block
0x2001
input 5
-
-
0x2002
-
Extended
diagnosis is
0x2003
available.
Fault code. See section "Error Handling, Maintenance and Service-> Fault Messages" for a description of the code.
The function of some bits can differ in case the control functions Actuator 1...4, Overload Relay or Transparent are configured.Please refer to the UMC100.3 manual in this case.
Bit 6
Bit 5
Summary
Local Control
Fault
UMC100 DI4
UMC100 DI3
Bit 6
Bit 5
Fault Reset
Auto Mode
UMC100 DO1
UMC100 DO0
-
-
-
-
Bit 6
Bit 5
PTC wiring
PTC hot
failure
UMC
Earth fault
self-test error
pre-warning
Trip/Warning
Trip/Warning
from
from
Aux-Fault
Aux-Fault
function
function
block input 4
block input 3
-
-
-
THD Warning
-
Cooling Time
Running
Parameter
-
out of range
Bit 4
Bit 3
Reverse
Overload
Lockout
warning
Time3
UMC100 DI2
UMC100 DI1
Bit 4
Bit 3
Prepare
-
Emergency
Start
UMC100 24V
-
DC Out
-
DX1xx
DO3
-
-
Bit 4
Bit 3
Pre-warning
Locked rotor
thermal
during
model
start-up
(stall)
Earth fault
I
trip (internal
above high
or externally
current
triggered)
warning
threshold
Trip/Warning
Trip/Warning
from
from
Aux-Fault
AuxFault
function
function
block input 2
block input 1
-
Trip triggered
from
Multifunction
input DI2
Voltage out of
Overload
spec
power
Just one start
Num Starts
left
Overrun
-
-
Bit 2
Bit1
Run Forward
Off
/ Opening
UMC100 DI0
Run
Fast
Forward
Bit 2
Bit1
Run
Off
Forward /
Opening
-
Run
Fast
Forward
DX1xx
DX1xx
DO2
DO1
-
-
Bit 2
Bit1
Phase
Phase
imbalance
loss
I
I
above high
below low
current trip
current
threshold
warning
threshold
HW fault on
Custom
IO module
application
error
Trip triggered
Trip triggered
from
from
Multifunction
Multifunction
input DI1
input DI0
Underload
-
power
-
-
-
-
Bit 0
Bit 8
Run
Reverse /
Closing
-
Bit 0
Bit 8
Bit 16
Bit 24
Run
Reverse /
Closing
-
DX1xx
DO0
-
Bit 0
Bit 8
Thermal
overload trip
I
below low
current trip
threshold
IO module
missing
Trip / Warning
from AuxFault
function
block input 6
-
-
-

Advertisement

loading

This manual is also suitable for:

Umc100.3