ETC Setup Guide
Rack-mount Repeater
Status Indicators
When power is applied to the Station Repeater Module, the LEDs located on the front panel will illuminate,
indicating the status of the auxiliary power, LinkConnect control network, and connected architectural
controls.
The Aux Power and LinkPower LEDs indicate in green when the module is connected properly and auxiliary
power and LinkPower are present.
• When there is an imbalance in LinkPower on the LinkConnect control run, the fault indicators
illuminate. This condition typically means that the station wiring has a fault, however it could mean
a connected device is having an issue. A qualified technician should inspect the system wire and
terminations first, then proceed to disconnecting devices to pinpoint the fault and correct it. The
power supply will update the fault indicators automatically when the fault condition is cleared.
• If the NET A line has a fault (is shorted or has leakage to ground), the Fault + LED lights.
• If the NET B line has a fault (is shorted or has leakage to ground), the Fault - LED lights.
• If neither fault LED is illuminated the data connections are properly installed and the stations are
receiving the data and power required for operation.
Rack-mount Repeater