Rack-mount repeater

Advertisement

Quick Links

ETC Setup Guide
Paradigm Rack-mount Repeater
The Paradigm Rack-mount Repeater adds support for more architectural control stations in the Paradigm
system.
The addition of a Rack-mount Repeater single model extends the station communication bus (LinkConnect)
length by 1,640 ft (500 m) and the Dual Station Repeater extends the station communication bus into two
segments of LinkConnect. Each repeater module type supports an additional 30 Paradigm control stations
or sensors on the topology-free and polarity-independent control network, and provides additional
auxiliary power for up to six Paradigm touchscreens. Station device counts cannot exceed the total capacity
allowed for the Paradigm system.
The installation procedure for the single and dual repeater models is identical.
Installation
1:
Locate the included rack mounting hardware kit including the mounting screws and washers.
2:
Use the hardware provided to mount the unit to the mounting rails in your equipment rack.
Power and Control Wiring
All power and control wire terminations are made to the rear panel of the unit.
AC Input
Single phase 115 VAC, 230 VAC, or 240 VAC power input to the IEC connector.
Corporate Headquarters Middleton, WI, USA +1 608 831 4116 London, UK +44 (0)20 8896 1000
Holzkirchen, DE +49 (80 24) 47 00-0 Rome, IT +39 (06) 32 111 683 Hong Kong +852 2799 1220 Paris, FR +33 1 4243 3535
Web
© 2019 Electronic Theatre Controls, Inc. Trademark and patent info:
Product information and specifications subject to change. ETC intends this document to be provided in its entirety.
7182M2261 Rev C Released 2019-07
etcconnect.com
Support
support.etcconnect.com
Contact
etcconnect.com/contactETC
etcconnect.com/ip
Single and Dual Repeater
models available.

Advertisement

loading

Summary of Contents for ETC Paradigm P-REP-RM

  • Page 1 Holzkirchen, DE +49 (80 24) 47 00-0 Rome, IT +39 (06) 32 111 683 Hong Kong +852 2799 1220 Paris, FR +33 1 4243 3535 etcconnect.com Support support.etcconnect.com Contact etcconnect.com/contactETC © 2019 Electronic Theatre Controls, Inc. Trademark and patent info: etcconnect.com/ip Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7182M2261 Rev C Released 2019-07...
  • Page 2 1,313 ft (400 m) between any two un-repeated communicating devices. ESD Ground Architectural controls must be grounded. ETC recommends running the LinkConnect wires through grounded metal conduit or pulling an additional 14 AWG (2.5 mm ) ESD ground wire per LinkConnect data run.
  • Page 3 ETC Setup Guide Rack-mount Repeater Pull a single ESD ground wire from the ground bar on the DRd or ERn enclosure if LinkConnect wiring is not installed in grounded metal conduit. ESD ground wires terminate to the ground bus located on the rear panel.
  • Page 4 ETC Setup Guide Rack-mount Repeater Status Indicators When power is applied to the Station Repeater Module, the LEDs located on the front panel will illuminate, indicating the status of the auxiliary power, LinkConnect control network, and connected architectural controls. The Aux Power and LinkPower LEDs indicate in green when the module is connected properly and auxiliary power and LinkPower are present.