General
Range
0.09 - 100 m
0.29 - 330 ft
Measuring accuracy*
± 2 mm
± 3/32 in
Smallest unit displayed
1 mm
1/16 in
Laser class
2
Laser type
635 nm, < 1 mW
Degree of Protection:
IP54
Autom. power switch-off
after 120 s
Continuous measuring
yes
Area / Volume
yes
120 x 45 x 24 mm
Dimension(LxWxH)
4.7 x 1.8 x 0.9 in
Battery durability (2 x AAA) up to 3000
measurements
Weight
81 g / 2.86 oz
(without batteries)
Temperature range:
-10 to 60 °C
- Storage
14 to 140 °F
0 to 40 °C
- Operation
32 to 104 °F
The typical measurement uncertainty of ± 2 mm
*
is valid for measurements on white, diffusive,
reflective targets up to 5 m at low ambient light
and moderate temperatures. For distances
greater than 5 m, the measurement uncertainty
could increase additionally by 0.1 mm/m. In
unfavourable conditions (such as bright sunlight,
targets with poor reflectivity, or high or low
temperatures) the measurement uncertainty
could further increase up to ± 4 mm for distances
below 5 m and additionally by roughly 0.15
mm/m for distances greater than 5 m.

Message Codes

If the message Error does not disappear after
switching on the device repeatedly, contact the
dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:
No.
Cause
Correction
101 The battery is out
Change batteries
of power
204 Measuring error
Restart measuring
252 Temperature too high
Let device cool down.
253 Temperature too low
Warm device up.
254 Out of measuring range
Correct range
255 Received signal too
Change target surface
weak, measuring time
(e.g. white paper) or
too long or outside of
correct range.
measuring range
256 Received signal too high
Change target surface
(e.g. white paper).
257 Too much background
Shadow target area.
light
294 The results out of
Get the results by
maximal digit on screen
changing units or calculate
manually
280 Module error
Restart the device
224 Hardware failure
Contact the dealer
Prexiso P100LCU

Care

• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or
solvents.

Disposal

CAUTION
Flat batteries must not be disposed
of with household waste. Care for
the environment and take them to
the collection points provided in
accordance with national or local
regulations. The product must not
be disposed with household waste.
Dispose of the product
appropriately in accordance
with the national regulations in
force in your country. Adhere to
the national and country specific
regulations. Product specific
treatment and waste management
can be downloaded from our
homepage.
EN
11

Advertisement

Table of Contents
loading

Table of Contents