Prexiso P40B-3LI Manual

Prexiso P40B-3LI Manual

Li-ion rechargeable pocket laser distance measure

Advertisement

Quick Links

IMPORTANT: Read before Using
®
P40B-3LI
L I - I O N R E C H A RG E A B L E P O C K E T
L A S E R D I S TA N C E M E A S U R E
2
LIMITED
WARRANTY
YEARS
www.prexiso-eu.com

Advertisement

Table of Contents
loading

Summary of Contents for Prexiso P40B-3LI

  • Page 1 IMPORTANT: Read before Using ® P40B-3LI L I - I O N R E C H A RG E A B L E P O C K E T L A S E R D I S TA N C E M E A S U R E...
  • Page 2: Table Of Contents

    - - - - - - - FCC statement (applicable in U.S.) • Do not operate the tool outdoors. - - - - - - - - - - - - - - - - - Laser classification Prexiso P40B-3LI...
  • Page 3: Instrument Set-Up

    P40B-3LI Open the cap On / Measure / and insert the Continuous USB recharging Measuring Area / cable with Volume/ Pythagoras Mirco-USB Port Units / (2-Point/ Measuring 3-Point) Recharge the device Reference Micro-USB when battery symbol shows empty. Prexiso P40B-3LI...
  • Page 4: Operations

    UNITS 00 1/16 3 sec 0 1/16 in 0.00 ft Change the measurement reference UNITS The system Press button default to change the measurements reference to start at the top for bottom as a measurement. reference point. Prexiso P40B-3LI...
  • Page 5: Measuring Functions

    Stops continuous measuring. 39'99" Aim active laser at target. Area The result is shown in the main line and the measured UNITS distance above. 29.99 Aim laser at first Aim laser at target point. second target point. Prexiso P40B-3LI...
  • Page 6: Volume

    The result is shown in the main line and the measured distance above. 29.99 Pythagoras(2-point) The result is shown in the Aim laser at Aim laser at main line and 90° 90° first target 39'99" second target the measured point. point. distance above. Prexiso P40B-3LI...
  • Page 7: Pythagoras(3-Point)

    Aim laser at 90° 90° second target Aim laser point(Perpen- at first dicular to the target measuring point. surface). The result is 90° laser at shown in the third main line and 39'99" target the measured point. distance above. Prexiso P40B-3LI...
  • Page 8: Technical Data

    0.082 lb 37 g Warranty • Clean the device with a damp, Temperature range: soft cloth. The Prexiso P40B-3LI has a two-year 14 to 140 °F • Never immerse the device in water. - Storage -10 to 60 °C warranty.
  • Page 9: Symbols Used

    Do not use Aiming directly in the sun • the product in explosion hazardous areas or in aggressive environments. Prexiso P40B-3LI...
  • Page 10: Areas Of Responsibility

    Maximum radiant output power energy and, if not installed and used in for classification: < 1 mW accordance with the instructions, may Pluse repetition frequency:320 MHZ cause harmful interference to radio Beam divergence:0.16mrad x 0.6mrad Prexiso P40B-3LI...

Table of Contents