Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P80 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Prexiso P80

  • Page 2: Table Of Contents

    Permitted use - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 Prohibited use - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 PREXISO P80 788508...
  • Page 3: Instrument Set-Up

    Insert batteries To ensure On / Measure reliable use, do not use zinc- Area / Volume / Add / Subtract carbon batteries. Pythagoras Change batteries when battery Measuring symbol is Memory reference / Unit flashing. Clear / Off PREXISO P80 788508...
  • Page 4: Operations

    Multifunctional endpiece Unit setting 2 sec The orienta- tion of the endpiece is Switch between the automatically following units: detected and 0.000 m the zero point is adjusted 0‘00‘‘ 1/16 accordingly. 0 in 1/16 PREXISO P80 788508...
  • Page 5: Measuring Functions

    The same process can be used for adding or subtracting areas or volumes. The next mea- The next mea- 7.332 surement is surement is 7.332 12.847 added to the subtracted from previous one. the previous one. PREXISO P80 788508...
  • Page 6: Area

    Volume Aim laser at first Aim laser at Aim laser at target point. second target third target point. point. The result is shown in the main line and the measured distance above. 78.694 PREXISO P80 788508...
  • Page 7: Pythagoras (2-Point)

    Pythagoras (3-point) Aim laser at Aim laser at Aim laser at upper point. rectangular lower point. point. The result is shown in the main line and the measured distance above. 8.294 PREXISO P80 788508...
  • Page 8: Memory (Last 10 Values)

    Measuring Functions Memory (last 10 values) 2 sec 8.294 8.294 Last 10 values Navigates back Value is ready are displayed. through last 10 to use for further values. calculations. PREXISO P80 788508...
  • Page 9: Technical Data

    Measuring accuracy between 10 m and 30 m may deteriorate to approx. ±0.15 mm/m, for distances above 30 m to ±0.2 mm/m. PREXISO P80 788508...
  • Page 10: Safety Instructions

    Changes or modifications not expressly mental damage. • Inadequate safeguards at the surveying approved by Prexiso for compliance could Important paragraphs which must be void the user’s authority to operate the site (e.g. when measuring on roads, adhered to in practice as they enable equipment.
  • Page 11: Areas Of Responsibility

    • Consult the dealer or an experienced requirements of the relevant standards Looking into the laser beam may be radio/TV technician for help. and regulations. hazardous to the eyes. However, the possibility of causing inter- ference in other devices cannot be totally excluded. PREXISO P80 788508...
  • Page 12: Labelling

    Laser Radiation Do not stare into the beam Laser class 2 acc. IEC 60825-1:2007 Maximum radiant power *: <1mW Emitted wavelength: 620-690nm Beam divergence 0.16 x 0.6 mrad Impulse duration 1 x 10 -9 s PREXISO P80 788508...

Table of Contents