Masport Westcott 1000 Operating Instructions Manual

Masport Westcott 1000 Operating Instructions Manual

Hide thumbs Also See for Westcott 1000:

Advertisement

Quick Links

Operating Instructions
Westcott 1000
Westcott 2000
Keep instructions for future reference
Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA

Advertisement

Table of Contents
loading

Summary of Contents for Masport Westcott 1000

  • Page 1 Operating Instructions Westcott 1000 Westcott 2000 Keep instructions for future reference Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS USER INSTRUCTIONS USER INSTRUCTIONS INTRODUCTION …………………………………………… 2 1. INTRODUCTION USING APPLIANCE FOR THE FIRST TIME ………. 3 RECOMMENDED FUELS ……………………………….. 3 Before use of this appliance please read these instructions LIGHTING THE FIRE ……………………………………… 3 fully. RUNNING THE APPLIANCE ………………………….. 4 WARNING: ANY MODIFICATION OF THE APPLIANCE THAT BURNING TIPS …………………………………………….
  • Page 3: Using Appliance For The First Time

    • Air Controls Keep the room well ventilated until these fumes have cleared. Primary air is controlled via the sliding vents (A - Fig 1) in the bottom of the door; this provides a conventional air draught to the bed of the fire. (+) indicates more air, (-) indicates less air, (+) and (-) are marked on the primary and secondary air 3.
  • Page 4: Running The Appliance

    5) Close door with both air slides fully open, and leave for 5. RUNNING THE APPLIANCE minimum of 10 minutes to allow the fresh wood to catch. Maximum Heat Output 6) After 10 or more minutes, shut the air slide in the door, •...
  • Page 5: Ash Removal

    • Blocked flue 8. FLUE/CHIMNEY FIRE For advice on the correction of persistent flue problems consult your supplier/installer for more detail. If a flue/chimney fire occurs: • Shut air slide controls fully to smother the fire • Do not use the appliance after a flue fire until an 7.
  • Page 6: Troubleshooting Tips

    • Alternatively, get a flue cleaning service to do the job The firebox of the Westcott 1000 and 2000 models are lined for you (it’s a dirty job). with vermiculite bricks. These help to maintain temperatures •...
  • Page 7: Replacement Of Baffle

    2. REPLACEMENT OF BAFFLE Remove the slotted log guard by raising it up, rotate on an angle into the firebox and remove through the door opening. Remove the side bricks as described in “1. Replacement of Firebricks”. Once removed, the baffle retainer with vermiculite insert can be removed through the door opening.
  • Page 8: Spare Parts

    5. SPARE PARTS Version 1.2...
  • Page 9 Version 1.2...
  • Page 10: Warranty

    This warranty is provided by Glen Dimplex Australia Pty Ltd. This warranty is provided to the first domestic purchaser of a Masport wood fire (radiant or convection). It applies from the date of purchase from or through an authorized Masport Fire Distributor in relation to each product or component for the period below.
  • Page 11 Version 1.2...
  • Page 12 Glen Dimplex Australia Pty Ltd 8 Lakeview Drive, Scoresby Victoria 3179 Australia T: 1300 556 816 | F: 1800 058 900 General & Sales Enquiries: flame@glendimplex.com.au Technical Service: service@glendimplex.com.au www.glendimplex.com.au Version 1.2...

This manual is also suitable for:

Westcott 2000

Table of Contents