Pentair BERKELEY 7FL Owner's Manual
Pentair BERKELEY 7FL Owner's Manual

Pentair BERKELEY 7FL Owner's Manual

Convertible deep well jet
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

owner's Manual
Convertible Deep Well Jet
5FL-L, 5FLJ, 7FL, 7FLJ
2760 0197
Installation/Operation/Parts
For further operating, installation, or maintenance assistance:
Call 1-888-782-7483
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.BERKELEYPUMPS.COM
PH: 888-782-7483
BE313 (Rev. 03/28/13)
© 2013 Pentair, Ltd. All Rights Reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BERKELEY 7FL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pentair BERKELEY 7FL

  • Page 1 Manual Convertible Deep Well Jet 5FL-L, 5FLJ, 7FL, 7FLJ 2760 0197 Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-888-782-7483 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.BERKELEYPUMPS.COM PH: 888-782-7483 BE313 (Rev. 03/28/13) © 2013 Pentair, Ltd. All Rights Reserved.
  • Page 2: Electrical Safety

    Safety READ AND FOLLOW ELECTRICAL SAFETY SAFETY INSTRUCTIONS! Capacitor voltage may be hazardous. To discharge motor capacitor, hold insulated handle This is the safety alert symbol. When you see this screwdriver BY THE HANDLE and short capacitor symbol on your pump or in this manual, look for terminals together.
  • Page 3: Typical Installations

    Typical Installations Piping omitted Suction Discharge for clarity "Double Pipe" "Single Pipe" (Larger) (4" and Larger (2" and 3" Port Diameter Well) Diameter Well) Drive Suction (Larger) (Smaller) Pipe from Well Port Drive (Smaller) Pipe to To Household Well Water System Well Drive Pipe Air Volume...
  • Page 4: Discharge Pipe And Pressure Tank Connections

    Discharge Pipe and Pressure Tank Connections PRE­CHARGE TANk CONNECTION (Figure 6) To Household Water System If your system uses a pre-charged tank, it should be connected to the pump Priming Port as shown in Figure 6. The relief valve must be capable of passing the entire pump capacity at 100 PSI pressure.
  • Page 5: Wiring Connections

    Electrical Disconnect power before working on pump, motor, pressure switch, or wiring. Your Motor Terminal Board (under the motor end cover) wiring if line voltage is 230 Volts or if you have a single and Pressure Switch look like one of those shown below. voltage motor.
  • Page 6: Preparing To Start The Pump - Deep Well

    Electrical Table I: Wiring Chart – Recommended Wire and Fuse Sizes Distance in Feet (Meters); Branch Wire Size AWG (mm Fuse Load Rating 0­100 101­200 201­300 301­400 401­500 Model Amps Amps (0­30) (31­61) (62­91) (92­122) (123­152) 5FL-L 9.4/4.7 15/15 14/14(2/2) 10/14(5.5/2) 10/14(5.5/2) 6/14(14/2)
  • Page 7 Preparing to Start the Pump – Deep Well Step 5. Deep Well only: When pressure has built up and stabilized at about 50 PSI, slowly open the control valve (see Figure 11) and let the pressure drop until the pressure gauge needle starts to flutter. When the needle flutters, close the valve just enough to stop the flutter (see Figure 11).
  • Page 8 Performance Table II – 4” Double Pipe Deep Well Performance and Ejector Chart ­ Ejector Package Bk4800 Model 5FL­L, 5FLJ Model 7FL, 7FLJ 1/2 HP 3/4 HP Feet to Pressure in psi Pressure in psi Water GPH w/J32P­24 Venturi & #51 Nozzle GPH w/J32P­32 Venturi &...
  • Page 9: Repair Parts

    Repair Parts 2591 0996 Repair Parts – Cast Iron Jet Pumps 5FLJ Part 5FL­L 7FLJ Description Qty. 1/2 HP 3/4 HP Motor, 115/230V A100CLL A100DLL Water Slinger 17351-0009 17351-0009 Seal Plate N3-9 N3-9 Seal Plate Gasket N20-35 N20-35 Shaft Seal U109-6A U109-6A Impeller...
  • Page 10: Troubleshooting

    Troubleshooting Troubleshooting Symptoms Things to Do: A. Motor will not run. A. Check that the disconnect switch is ON and that the circuit breaker has not tripped or the fuse has not blown. DISCONNECT POWER and make sure that wires connecting motor to power supply and pressure switch are tight and correctly connected (see Page 6).
  • Page 11: Warranty

    Warranty Limited Warranty BERKELEY warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period Water Systems: whichever occurs first: Water Systems Products —...
  • Page 12 This page intentionally left blank...
  • Page 13 5FL-L, 5FLJ, 7FL, 7FLJ 2760 0197 Installation/Fonctionnement/Pièces Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien, Composer le 1 (888) 782-7483 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.BERKELEYPUMPS.COM PH: 888-782-7483 BE313 (Rév. 28/03/13) © 2013 Pentair, Ltd. All Rights Reserved.
  • Page 14: Sécurité Générale

    Sécurité LIRE TOUTES CES INSTRUCTIONS SÉCURITÉ CONCERNANT L'ÉLECTRICITÉ ET LES SUIVRE! La tension du condensateur peut être dangereuse. Pour décharger le condensateur du moteur, tenir Ce symbole indique qu'il faut être prudent. Lorsque ce un tournevis à manche isolé PAR LE MANCHE et mettre en symbole apparaît sur la pompe ou dans cette Notice, court-circuit les bornes du condensateur.
  • Page 15: Installations Typiques

    Installations typiques Tuyauterie non Piping omitted montrée pour plus de Suction Discharge for clarity «Deux tuyaux» "Double Pipe" «Un seul tuyau» clarté "Single Pipe" Refoulement Aspiration (Larger) (Le plus (4" and Larger (puits de 4 po de dia. (puits de 2 (2"...
  • Page 16 Branchements du tuyau de refoulement et du réservoir sous pression Vers le système d’eau de la maison To Household Water BRANCHEMENT SUR UN RÉSERVOIR PRÉCHARGÉ (Figure 6) System Si le système est branché sur un réservoir réservoir préchargé, il devra être branché Priming Port Orifie d’amorçage sur la pompe, comme il est illustré...
  • Page 17 Électricité Débrancher le courant électrique avant d'intervenir sur la pompe, le moteur, le manostat ou le câblage. La plaquette de connexions du moteur (qui se trouve sous le la tension est de 230 volts ou si le moteur ne fonctionne que couvercle d'extrémité...
  • Page 18: Préparations Avant Le Démarrage De La Pompe - Puits Profond

    Électricité Tableau I : Câblage ­ Câbles et diamètres des fusibles recommandés Distance en pieds (mètres); Fusible Diamètre de fils ­ calibre AWG (mm Charge Intensité max. en 0­100 101­200 201­300 301­400 401­500 Modèle ampères ampères (0­30) (31­61) (62­91) (92­122) (123­152) 5FL-L 9,4/4,7...
  • Page 19 Préparations avant le démarrage de la pompe - Puits profond 5 ° Puits Profond Seulement: Lorsque la pression s’est accumulée et stabilisée à environ 50 lb/po , ouvrir lentement la vanne de réglage (voir la Figure 11) et laisser chuter la pression jusqu’à ce que l’aiguille du manomètre commence à...
  • Page 20 Rendement TABLEAU II – Tableau de rendement avec des puits profonds de 4 po à deux tuyaux et des éjecteurs ensemble d’éjecteur Bk4800 Modèle 5FL­L, 5FLJ Modèle 7FL, 7FLJ 1/2 de ch 3/4 de ch Mètres jusqu’à Pression en lb/po Pression en lb/po l’eau L/h avec venturi J32P­24 et ajutage n°...
  • Page 21: Pièces De Rechange

    Pièces de rechange 2591 0996 Pièces de rechange ­ pompes en fonte à éjecteur 5FLJ 5FL­L 7FLJ Réf. Description Qté 1/2 Ch 1/2 Ch Moteur, 115/230V A100CLL A100DLL Déflecteur d’eau 17351-0009 17351-0009 Plaque d’étanchéité N3-9 N3-9 Joint de plaque d’étanchéité N20-35 N20-35 Joint d’arbre...
  • Page 22: Diagnostic Des Pannes

    Diagnostic des pannes Symptômes Quoi faire : A. Le moteur ne tourne pas. A. S’assurer que le sectionneur est sur MARCHE et que le disjoncteur ne s’est pas désenclenché ou que le fusible n’a pas sauté. COUPER LE COURANT D’ALIMENTATION et s’assurer que tous les fils raccordant le moteur au courant d’alimentation et au manocontacteur sont bien serrés et bien branchés (voir la page 16).
  • Page 23: Garantie

    Garantie Garantie limitée BERKELEY garantit au consommateur initial (ci-après appelé l’« Acheteur ») que les produits énumérés dans les présentes sont exempts de défaut de matériau et de fabrication pendant la durée des garanties à compter de la durée des garanties indiquées ci- dessous.