Test Condition; Operating Range; Power Supply; Operation - Mitsubishi Electric MUZ-FS06NA Service Manual

Outdoor unit
Hide thumbs Also See for MUZ-FS06NA:
Table of Contents

Advertisement

Test condition

*3, *4
Mode
AHRI
210/240
"A-Full" Cooling Steady State
at rated compressor speed
"B-Full" Cooling Steady State
at rated compressor speed
SEER
"B-Low" Cooling Steady State
(Cooling)
at minimum compressor speed
"F-Low" Cooling Steady State
at minimum compressor speed
"E-Int" Cooling Steady State
at intermediate compressor speed *5
"H1-Nom" Heating Steady State
at rated compressor speed
"H3-Full" Heating
at rated compressor speed
HSPF
"H0-Low" Heating Steady State
(Heating)
at minimum compressor speed
"H1-Low" Heating Steady State
at minimum compressor speed
"H2-Int" Heating
at intermediate compressor speed *5
*5 : At intermediate compressor speed
= ("Rated compressor speed" - "minimum compressor speed") / 3 + "minimum compressor speed".

OPERATING RANGE

(1) POWER SUPPLY

Rated voltage
208/230 V
Outdoor unit

(2) OPERATION

Mode
Condition
Standard temperature
Maximum temperature
Cooling
Minimum temperature
Maximum humidity
Standard temperature
Heating
Maximum temperature
Minimum temperature
OBH873
Test
Guaranteed voltage (V)
Min. 187
1 phase
60 Hz
DB
80
90
67
70
80
70
Indoor air condition (°F)
Dry bulb
Wet bulb
80
80
80
80
80
70
70
70
70
70
208
230
Max. 253
Intake air temperature (°F)
Indoor
WB
67
73
57
78 %
60
67
60
5
Outdoor air condition (°F)
Dry bulb
67
95
67
82
67
82
67
67
67
87
60
47
60
17
60
62
60
47
60
35
Outdoor
DB
95
115
14
47
75
-13
Wet bulb
(75)
(65)
(65)
(53.5)
(69)
43
15
56.5
43
33
WB
43
65
-14