TROUBLESHOOTING

Problem
Possible causes
Product refuses to
Product not plugged in
start
Defective socket
Defective extension cable
Fluctuating pressure
Pump sucking air
Valves dirty, worn out or stuck
Pump seals worn out
Product stops
Fuse has blown
Incorrect mains voltage
Thermal sensor activated
Nozzle partially blocked
Product pulsating
Air in inlet hose/pump
Inadequate
water
Nozzle partially blocked
Water filter blocked
Hose kinked
Product often starts
Pump/spray handle is leaking
and stops by itself
Product starts, but
Pump/hoses or accessory frozen
no water comes out
No water supply
Water filter blocked
Nozzle blocked
No detergent
Nozzle adjusted to high pressure
Tank is empty.
Solution
Plug in product.
Try another socket.
Try without the extension cable.
Check that hoses and connections are air tight.
Bring the product to an authorized service centre for service
or repair.
Bring the product to an authorized service centre for service
or repair.
Bring the product to an authorized service centre for service
or repair.
Check that the mains voltage corresponds to specification
on the model tag.
Leave the cleaner for 15 minutes to cool down.
Clean the nozzle.
Allow the product to run with open trigger until regular
working pressure resumes.
supply
of
mains
Check that the water supply corresponds to the specifications
required (see model tag). Avoid using long, thin hoses.
Clean the nozzle.
Clean the filter.
Straighten out hose.
Bring the product to an authorized service centre for service
or repair.
Wait for pump/hoses or accessory to thaw.
Connect the water inlet port to a water supply.
Clean the filter.
Clean the nozzle.
Adjust to low pressure.
Fill the tank.