Kse series bi-directional energy-storage inverter (45 pages)
Summary of Contents for KStar KSG-DM 10kW
Page 1
Type: Solar On Grid String Inverter Models: KSG-DM 10kW |1 2kW | 15kW| 17kW| 20kW , KSG-TM 30kW | 50kW | 60kW CONNECTION DIAGRAM The communication terminals (RS485) are located at the bottom of the inverter. And there are two connection terminals on the configuration circuit board: ++ - - terminal blocks.
Page 2
Multiple Inverters Pin 2 & 4 of Inv-1 is connected to Pin 1 & 3 of next inverter in Daisy Chain. When two or more inverters are in parallel communication, 2P DIP switch beside RS485 of the last one should be “ON”.
ENTER button,press ESC button to cancel choice and return back setup interface NOTE: The above details are mentioned in the Installation & Operation Manual for Kstar KSG-30K/36K/50K/(60K- HV)/60K on Page 28.
Page 4
TRACKSO WORKING 1. Insure correct connections as detailed in the installation guide. 2. Insert the SIM card. 3. Switch on the power to the TrackSo device. (Minimum 12V/1A input is required) 4. Power LED (Red) of TrackSo IoT gateway glows and stays ON. NOTE: TrackSo IoT Gateway will only be able to send data if the GPRS network is available at the installed location.
Page 5
5. To check the exact network status send the following message to mobile number of the device SMS Command= *2222#<Stat.gsm> IMEI IMEI No. of the data logger (Device Key) Network SIGN Signal Strength out of 31 GPRS CONT- connected , NC- not connected Connected to TrackSo Server or not CONT- connected, NC- not connected no.
Page 6
9. If the state remains Not receiveing for more than 10 minutes, click on your email ID at the top right of the screen and click on ‘Event Ingestion Logs’ in the dropdown. 10. Check if there is some log generated at the time of installation of the TrackSo IoT Gateway device. a.
This manual is also suitable for:
Ksg-dm 12kwKsg-dm 15kwKsg-dm 17kwKsg-dm 20kwKsg-tm 30kwKsg-tm 50kw...
Show all