0A-30
General Information
1. Completely remove lubricant and moisture from the connecting surfaces.
The surfaces must be perfectly dry.
2. Apply specified bead width of liquid gasket to one of the connecting surfaces.
There must be no gaps in the bead.
SCREW
HOLE
1 3
(0.04 0.12)
1 3
(0.04 0.12)
NOTE:
If the repair manual specifies an application method,
follow that method.
mm (in)
JUDGE
DEPRESSION
MENT
OK
More than
2 (0.08)
OK
NG
Depression
Example
Apply liquid gasket to
the bolt hole interior
Specified
bead width
Anaerobic Type :2-3 mm (0.08-0.12 in)
Others
:2-6 mm (0.08-0.24 in)
MFW70AMF000101