MEX-GS810BH/N6000BH
DESTINATION SETTING METHOD
When the complete MAIN board or IC502 on the MAIN board is
replaced, the destination setting is necessary.
1. Destination Setting
Set destination according to the procedure below.
1-1. Setting the Destination Code
1. In the state of source off (the clock is displayed on the liquid
crystal display), enter the test mode by pressing the buttons in
order of the [
4] t [MIC 5] t [PAUSE 6] (press only the
[PAUSE 6] button for two seconds).
2. In the state in which the software main version is displayed on
the liquid crystal display (refer to following fi gure), enter the
destination setting mode by pressing the buttons in order of the
[
SEEK+] t [SEEK–
> M
VOICE/ APP].
(Displayed characters/values in the following fi gure are ex-
ample)
Software main version
3. Input the alphanumeric character of 12 digits of "F XXXXXX"
displayed on the liquid crystal display, and execute the destina-
tion setting.
Note: Refer to following "1-3. Entering the Destination Code" for opera-
tion method.
4. The resetting operation is executed by pressing the [ OFF
SRC] button for 1 second after the setting ends, and the unit
returns to the normal condition.
1-2. Display in Destination Setting Mode
(Displayed characters/values in the following fi gure are example)
Destination code
OP5 OP4 OP3 OP2 OP1 OP0
12 digit
4
] t [PUSH ENTER/
m .
1-3. Entering the Destination Code
Method of operation by main unit
1. Rotate the control dial, and select the alphanumeric character
of "0 to F".
2. The digit advances by pressing the [PUSH ENTER/VOICE/
APP] or [
SEEK+] button.
> M
The digit returns by pressing the [MODE
] button.
.
3. The setting is completed by pressing the [PUSH ENTER/
VOICE/ APP] button, and the initialization operation is done.
Method of operation by remote commander
1. Press the [ V ] or [ v ] button, and select the alphanumeric char-
acter of "0 to F".
2. The digit advances by pressing the [ b ] button.
The digit returns by pressing the [ B ] button.
3. The setting is completed by pressing the [ENTER] button, and
the initialization operation is done.
1-4. Destination Code
Model
Destination
MEX-GS810BH
US
MEX-N6000BH
US
] or [SEEK–
m
OP5 OP4 OP3 OP2 OP1 OP0
7
2
8
7
1
2
4
2
8
7
0
2
– Continued on next page –