Download Print this page

Reset Device - B meters RFM-LR1 Quick Start Manual

Lorawan module for gsd8-rfm water meter

Advertisement

Examples
Uplink:
012100001738
Normal Volume with the meter reading 5944 liter
Uplink:
012100001738012008
Normal Volume with the meter reading 5944 liter combined with Status data indicating Module removed alarm flag
Downlink:
012000 Uplink:
Resets all alarm flags
Downlink:
012205A0 Uplink:
Sets the Reporting interval to 1440 minutes = 24 hours.
Downlink:
0227
Uplink: 012700000017
Query the Back flow volume. The reply is 23 liter.

Reset device

The device can be remotely reset and forced into Joining state. All settings are back to factory default.
Example
Remote device reset:
RFM-LR1
012000
012205A0
Port 1: 0305
9