Physical Installation - B meters RFM-LR1 Quick Start Manual

Lorawan module for gsd8-rfm water meter

Advertisement

There are at least five startup transmissions. The Status command (index 0x20) is sent unless a reply to a
downlink is sent. If no replies are sent the Status commands are sent with increasing intervals starting with
15 seconds and ending with two minutes. This startup sequence should be utilized to set the starting value of
the water meter (if not equal to 0 m
). For accurate calibration, the water meter should not be used during the
3
calibration.

Physical installation

When the meter has been digitally configured into your Lora network it is time to physically activate and install
it. The installer mounts the RFM-LR1 unit on the GSD8-RFM and mount the locking pin and seal.
Physical installation process
1.
Mount RFM-LR1 unit on the water meter
2.
Mount the locking pin and seal
If you require further support, please contact support@bmeters.com or your vendor.
Activating on the network
Standard devices are configured to use OTAA (Over The Air Activation). It is possible to order a batch of devices
configured for ABP (Activation By Personalization).
Standard devices are configured with the AppEUI (a.k.a. JoinEUI) 70-B3-D5-D7-2F-F8-1301. It is possible to
order a batch of devices configured with a customer unique AppEUI for this contact B METERS support.
Upon receiving your RFM-LR1 you can request from B METERS the necessary information to connect it to your
network server. This consists of the following:
1. DevEUI
2. AppKey
These codes are unique for each device. The DevEUI can be seen as a unique identification code, the AppKey is
a securely generated authentication code.
3
RFM-LR1
User Manual v1.1