PARTS DESCRIPTION
1. Fan guard
2. Fan blade
3. Speed switch
4. Battery indicator lights
5. Battery charging socket
6. USB charging socket
7. Stand
8. Power adapter
OPERATING INSTRUCTIONS
Rotate the speed switch to turn on the fan, and the air speed increases in the arrow's direction. To turn the
fan off, just rotate the speed switch back to the position "OFF".
There is a row of indicator lights which illuminate to show the corresponding percentage of battery
remained.
When using with the power adapter, first connect the power cord with the battery charging socket, and
then plug the adapter to a suitable power outlet. Make sure that the voltage of the power adapter is in
conformity with the local power condition.
USB charging socket can provide charging for digital devices such as mobile phone with DC5V output voltage
and 1A current.
Tilting angles: By pushing the fan-guard, you can adjust the fan to the preferred elevation.
Notes:
When the fan is off and charging with the power adapter for some time, the lights will all illuminate, and
about 10 minutes later, these lights will be turned off automatically, at this time, the fan's battery is fully
charged.
It's not recommended to use the USB charging function when the fan's battery is no more than 20%.
The appliance has a thermal protection device and overcurrent protective device. When the appliance
overheats due to various reasons, it will cut off the circuit of the fan automatically and make the fan safe. If
the thermal protection device or overcurrent protective deivce operate, you should have the fan examined
and eliminate the trouble. If necessary, send the fan to qualified persons for repair.
CLEANING
1.
Before servicing the fan and after each occasion of use, switch off the appliance and unplug the mains cable
from the socket.
2.
Never immerse the appliance in water (danger of short-circuit). To clean the appliance, only wipe it down
with a damp cloth and dry it carefully. Always take out the mains plug first.
3.
Take care that excessive dust does not build up in the air-intake and air-outlet grille, and clean it occasionally
using a dry brush or vacuum cleaner.
TECHNICAL DATA
Adaptor input: 100-240V~, 50/60Hz, 1A
Adaptor output: 24V
Fan input: 24V
1A
Use only with TP04-240150E supply unit
- 45 -
1.5A
FN-120708.1 / FN-120708.2