Panasonic EVERVOLT EVPV Series General Installation Manual page 9

Photovoltaic module
Table of Contents

Advertisement

MOUNTING WITH CONTINOUS RAILS PARALLEL TO SHORT SIDE OF THE MODULE
Continous rail spans the complete underside of the module.
0
23.8 in [605 mm]
22.2 in [565 mm]
13.4 in [340 mm]
8.2 in [208 mm]
Figure 7. Clamping of modules with rails parallel to short side of the module
Legend
Clamping zone
Rail position
Rail position
Once a module is secured in each of the 4 zones (fig. 2), additional clamps, i.e., ≥5 may be freely located on panel frame
without affecting the warranty. Loads marked with a * were not certified as part of UL 61730 testing; these have been
evaluated by internal testing process.
CAUTION
The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to be
rated to that load (Figure 7).
If the panel is secured in zones with different load values, it is rated to the lowest load value only.
General Installation Manual
27.4 in [695 mm]
0.8 - 1.6 in (20-40 mm)
Clearance Gap
Test Load
(Design Load)
0 - 8.2 in
X
(0 - 208 mm)
8.2 - 13.4 in
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
(208 - 340 mm)
13.4 - 22.2 in
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
(340 - 565 mm)
22.2 - 23.8 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(565 - 605 mm)
23.8 - 27.4 in
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
(605 - 695 mm)
0 - 4 in
X
(0 - 100 mm)
4 - 9.8 in
X
(100 - 250 mm)
27.4 in [695 mm]
23.8 in [605 mm]
22.2 in [565 mm]
13.4 in [340 mm]
8.2 in [208 mm]
1.6 - 2.4 in (40-60 mm)
Test Load
(Design Load)
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+4200 Pa / -2400 Pa
(+2800 Pa / -1600 Pa)
+6200 Pa / -4000 Pa
(+4133 Pa / -2666 Pa)
+3000 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
0
>2.4 in (>60 mm)
<0.8 in (<20 mm)
Test Load
Test Load
(Design Load)
(Design Load)
+2400 Pa / -2400 Pa
X
(+1600 Pa / -1600 Pa)
+5400 Pa / -2400 Pa
X
(+3600 Pa / -1600 Pa)
+7000 Pa / -4000 Pa
X
(+4666 Pa / -2666 Pa)
+5400 Pa / -2400 Pa
X
(+3600 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
X
(+1600 Pa / -1600 Pa)
+1600 Pa / -1600 Pa *
X
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
X
(+1600 Pa / -1600 Pa)
8

Hide quick links:

Advertisement

Table of Contents
loading