BARRON Exitronix NXFX Series Installation Instructions Manual

BARRON Exitronix NXFX Series Installation Instructions Manual

Advertisement

Quick Links

NXFX Series
Installation Instructions
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
When using electrical equipment, basic safety precautions should always be followed including the following:
• DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
• Installation and servicing of this equipment should be performed by qualified service personnel only.
• Ensure that the electrical wiring conforms to the National Electrical Code NEC® and local regulations,
if applicable.
• Do not mount near gas or electrical heaters.
• Equipment should be mounted in locations and at heights where it will not be readily subjected to tampering
by unauthorized personnel.
• For 2CI operation - ensure that both AC power and auxiliary power are not simultaneously live.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
• Any modification or use of non-original components will void the warranty and product liability.
• Do not use this equipment for other than intended use.
• Allow battery to charge for 24 hours before first use.
10070226 REV 1 - 08/20
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS!
Technical Support
■ (623) 580-8943 ■ technicalsupport@barronltg.com
1
800-533-3948 www.barronltg.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Exitronix NXFX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BARRON Exitronix NXFX Series

  • Page 1 NXFX Series Installation Instructions IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. When using electrical equipment, basic safety precautions should always be followed including the following: • DISCONNECT AC POWER SUPPLY BEFORE SERVICING. • Installation and servicing of this equipment should be performed by qualified service personnel only. •...
  • Page 2 NXFX Series Installation Instructions Ceiling or End Mount (Fig. 1a) 1. Remove the lens by removing the (6) screw caps and the (6) screws with O-rings and set all aside. 2. Remove the EXIT template and diffuser and set both aside. 3.
  • Page 3 NXFX Series Installation Instructions Ceiling or End Mount, Continued 12. Replace the inner frame using the (4) screws from Step 3. 13. Remove the chevron(s) from the EXIT template, if desired. 14. Replace the diffuser and EXIT template. 15. Replace the lens and secure using the (6) screws with O-rings from Step 1. Ensure the O-rings make a proper seal. 16.
  • Page 4 Installation Instructions Wall Mount Using Mounting Brackets (Fig. 3) Note: For optimal weatherproofing when using the mounting brackets, Barron Lighting recommends using flexible, UL Listed for Wet Location conduit as the means to provide line voltage to the unit. Use flexible conduit only; not for use with rigid conduit.
  • Page 5: Electrical Connections

    NXFX Series Installation Instructions Electrical Connections Fig. 4 - AC Only All electrical connections should be made inside Red (277VAC) the J-box. Make electrical connections as follows: Note: Cap unused leads to prevent shorting. Black (120VAC) Indicator Transformer White (Com) AC Only or With Battery Models (Fig.
  • Page 6: Operation

    NXFX Series Installation Instructions Self-Test/Self-Diagnostics (G2) Operation The purpose of this option is to provide Self-testing and Self-diagnostic capabilities to the EXIT sign. At predetermined intervals, the EXIT sign will automatically switch into battery mode. Refer to the Self-Test Features section of this page for timing details.