Replacing The Power Cable; Cleaning, Maintenance And Ordering Of Spare Parts - Pattfield Ergo Tools PE-SW 3030 Original Instructions Manual

Dirty water pump 300 w
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 141
When adjusting the floating switch, make sure that the floating
switch does not touch the bottom before the equipment is swit-
ched off. Important! Risk of dry running.
Manual operation:
Mount the fl oat switch as illustrated in Figure 3 so that the device
runs continuously. In this mode the equipment may be used only
under supervision to avoid dry running. The equipment must be swit-
ched off (pull out the power plug) as soon as no more water is emit-
ted from the discharge line.

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged, it must be replaced
by the manufacturer or its after-sales service or similarly trained per-
sonnel to avoid danger.

8. Cleaning, maintenance and ordering of spare parts

GB
Danger!
Unplug the power plug prior to any maintenance work.
For mobile applications, the equipment should be cleaned with
clear water after every usage.
For stationary installation, it is recommended that you check the
floating switch for proper operation every three months.
Use a water jet to remove any lint or fibrous particles that may
have become trapped in the housing.
Remove sludge from the shaft bottom and clean the shaft walls
every 3 months.
Use clear water to remove deposits from the floating switch.