Technical Data - GEM 9428 Operating Instructions Manual

Motorized quarter turn actuator
Table of Contents

Advertisement

7 Technical data

7.1 Temperature
Ambient temperature:
Storage temperature:
7.2 Product compliance
Machinery Directive:
EMC Directive:
Low Voltage
Directive:
7.3 Electrical data
Duty cycle:
Electrical protection:
Electrical protection
class:
7.3.1 Electrical connection
Electrical connection
type:
Cable diameter:
Max. cross section of wire: 1.5 mm²
Recommended motor
protection:
Rated voltage:
Rated frequency:
www.gemu-group.com
-10 to 60 °C
0 to 40 °C
2006/42/EC
2014/30/EU
2014/35/EU
Supply voltage 12 V / 24 V: Continuous duty
Supply voltage 100 - 250 V: 40 % duty
Supply voltage 12 V / 24 V:
Motor protective system by customer
Supply voltage 100 - 250 V:
Integrated stall and overload protection
plus excess current release T 1A 5x20 mm
I (DIN EN 61140)
Supply voltage 12 V / 24 V: Cable gland PG 13.5
Supply voltage 100 - 250 V: Hirschmann plug Type N6RFFS11 (PG 11)
Supply voltage 12 V / 24 V: 7.5 to 12.5 mm
Supply voltage 100 - 250 V: 7.0 to 9.0 mm
Voltage
Motor protection
Siemens 3RV
switch type
1011-1CA10
Set current
Current data in A
12 V / 24 V AC or DC (± 10 %)
100 – 250 V AC (± 10 %)
50/60 Hz (at AC rated voltage)
12 V DC
24 V DC
Siemens 3RV
1011-1BA10
2.20
1.70
9 / 36
7 Technical data
120 V AC
230 V AC
Siemens 3RV
Siemens 3RV
1011-OGA10
1011-OGA10
0.60
0.45
GEMÜ 9428