DESCRIPTION

The 2091 Megapower Code Converter receives high speed
code from a 1024 CPU and converts the code into
Control Code which is used by all standard American
Dynamics receiver/drivers.
switching information for monitors 1-8, when used with the
American Dynamics' 1631 Switcher Follower.
The 2091 unit provides for 64 code outputs in four groups of
16. The codes provide for controlling pan/tilt, lens, zoom,
focus, and iris; and auxiliaries at suitably-equipped camera
sites.
Control signals are received via the DATA LINE (older
systems used the term LAN). Each of the four groups can
control a block of 64 cameras which is selectable via the dip
switches located next to each group on the rear panel.
If conversion to RS-232 is required, a DIP switch, located on
the main printed circuit board, is used to select the mode and
the baud rate.

FEATURES

The 2091 Code Converter has the following features:
SCREW TERMINAL WIRE CONNECTORS
LED INDICATORS FOR "GOOD" CODE
GREEN LED POWER INDICATOR
DIP SWITCH SELECTION FOR CAMERA GROUP
FOR CONTROL
BAUD RATE SELECTABLE RS-232 OUTPUT FOR
USE WITH MODEMS OR OTHER DEVICES
UNIVERSAL MOUNT CABINET
IF YOU ENCOUNTER ANY PROBLEMS
OPERATING THIS UNIT, OR NEED TECHNICAL
ASSISTANCE, CALL OUR SERVICE CENTER AT:
within the United States: 1-800-442-2225
outside the United States: (845) 624-7600
The 2091 also filters camera

INSTALLATION

Power Sources
System models with the 'AD' prefix are configured for 120V,
50/60 Hz primary power source. Models with the 'AD'
prefix and "-1" suffix are configured for a 230V, 50/60 Hz
primary power source, and are EU compliant. The 120 VAC
units are supplied with a pendant 3-wire cord and plug for
mating to the primary source outlet. The 230 VAC units are
supplied with a Euro-style IEC 320 type inlet. A suitable,
detachable cord should be connected between the IEC 320
inlet and the power source. The cord should conform to all
national and local use code requirements.
The 2091 Megapower Code Converter does not contain an
On/Off Switch. The LED on the rear panel labeled Power, will
be lit when power is applied. Power consumption for the 2091
is approximately 7 watts.
Do not connect the equipment to the power source until
ready to "POWER UP". The socket outlet shall located
near the equipment, and shall be readily accessible.

MOUNTING

The universal cabinet may be surface or full-rack mounted in
any convenient location with adequate ventilation.
As shipped, with the mounting ears flush with the front panel,
the 2091 can be mounted into the front of a standard 19" rack.
The "ears" can be un-screwed and mounted so they fit flush
with the rear panel. This configuration provides for mounting
into a rack equipped with mounting channels located on the
rear of the rack. The 2091 unit can also be mounted to the wall
by mounting the ears so they are either up or down with the top
and bottom covers of the unit.
Optimally, the 2091 should be located near the 1024
CPU and 1024 switching bays.
Avoid heat sources or poorly ventilated racks. For proper
ventilation allow at least 3 feet (1m) from the rear of the racks
to any wall and 1 EIA rack height, 1 3/4", between units. The
2091 operates properly between +32 degrees and +140 degrees
Fahrenheit (0 to +60 degrees Centigrade).
Operating power voltages must be held within 230V and 250V
for 'AD/-1' units.
Safeguards must be taken to avoid unintentional operation
by employees and maintenance personnel working about
the premises, by falling objects, by customers, by
building vibration, and by similar causes.