Summary of Contents for HYDAC FILTER SYSTEMS CSI-C-11
Page 1
CSI-C-11 ConditionSensor Interface Operating Instruction English • (translation of original instructions) Document No. : 4486210 • 11/19/2019 Follow these instructions for proper and safe use. Keep for future reference.
Proper/Designated Use.................. 21 Improper Use or Use Deviating from Intended Use ........ 22 Technical Data .................... 23 Decoding the model code label.............. 25 3.6.1 Model code .................. 26 4 Storage and transport ..................... 27 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Page 3
Sending an e-mail notification ................ 53 7.3.1 Example - E-mail settings on the web server ........ 54 8 Performing Maintenance .................. 55 9 Troubleshooting/fault rectification ................ 56 10 Removing / Disposal .................... 59 11 Appendix ......................... 60 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
The contact data of the person authorized with the documenta- tion is: Mr. Günter Harge c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar Germany Phone: +49 6897 509 1511 Fax: +49 6897 509 1394 E-mail: guenter.harge@hydac.com Tab. 2: Documentation Representative BeWa CSI-C-11 4486210 from_V240_up en-us lq 5 / 72...
Observe the additional product-related in- structions and requirements. Specialist person- Read, observe and follow this manual and the associated documents, in particular, the safety and warning instructions. Tab. 3: Target group 6 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Operation, Specialist Knowledge of using Windows operations control PCs/mobile end devices. Product-specific knowledge. Dismantling, Specialist Proper and environmentally disposal friendly disposal of materials and substances. Knowledge about reuse. Tab. 4: Required qualifications/training BeWa CSI-C-11 4486210 from_V240_up en-us lq 7 / 72...
Supplementary instructions regarding the validity of the manual (optional) Please note that you can directly access information through the directories. However, this does not release you from the obligation to read this manual fully before commissioning. 8 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
1. Remove the transport securing device. 2. First fill the product. 3. Switch the product on. Procedural instructions with a random sequence Procedural instructions that have a random sequence are listed as bullet points (-). BeWa CSI-C-11 4486210 from_V240_up en-us lq 9 / 72...
An example for a procedural instruction with intermediate re- sult and final result: 1. Switch the product on. ð The display lights up. 2. Press the button. O The product is now ready for use. 10 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Warning / general safety information, which are placed ahead of each activity, are represented as follows: CAUTION Type and source of danger Consequence of the danger Hazard symbol Measures to avert danger ► BeWa CSI-C-11 4486210 from_V240_up en-us lq 11 / 72...
NOTICE NOTICE – The signal word indicates a hazardous situation with a high level of risk, which, if not avoided, will result in damage to property. 12 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Follow the instructions. Signs used for the required specialist personnel These symbols show the required training/knowledge for in- stallation work and/or maintenance work. BeWa CSI-C-11 4486210 from_V240_up en-us lq 13 / 72...
The diagrams and visualizations in this manual are meant for general illustration purposes. Therefore, representations and functional options can deviate from the delivered product. We reserve the right to changes to the contents of this manual without prior notice. BeWa CSI-C-11 4486210 from_V240_up en-us lq 15 / 72...
Take note of different bus addresses of the HYDAC SMART sensors. NOTICE Wrong sensor Erroneous or no communication. u Connect the CSI-C-11 only with HYDAC SMART sensors or the permitted analog sensors. NOTICE Connecting more than two HYDAC SMART sensors Erroneous or no communication.
Page 17
Erroneous or no communication. u Connect a maximum of 4 permitted analog sensors to the CSI-C-11. NOTICE Exceeding the maximum permissible line length Erroneous or no communication. u Observe the maximum permissible line lengths. BeWa CSI-C-11 4486210 from_V240_up en-us lq 17 / 72...
Limit values are set according to the measured variable with the aid of an assis- tant. If a limit value is exceeded, the CSI-C-11 will automati- cally send out an alarm via e-mail or the Ethernet and fieldbus interface (Modbus®).
3 | Product overview HYDAC FILTER SYSTEMS GMBH 3.2 Dimensions The CSI-C-11 has the following dimensions. Fig. 2: CSI-C-11 dimensions All dimensions in mm. 20 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
RTU) which can be transmitted both by cable (LAN) and wirelessly (WLAN) to stationary (e.g. desktop PC) and mo- bile end devices (e.g. smartphone). In addition, the CSI-C-11 has an internal memory through which the interface module can also be used as a data logger. Depending on the type of device, for example, two HYDAC SMART sensors and four analog sensors can be connected.
– Operation with non-approved sensors. – Operation with more than two HYDAC SMART sensors. – Operation with more than four analog sensors. – Modifications to the interface made by the user or pur- chaser. 22 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
HYDAC FILTER SYSTEMS GMBH Product overview | 3 3.5 Technical Data The CSI-C-11 has the following technical data: HSI interface HYDAC Sensor Interface for the connection of two HYDAC SMART sensors Analog interface Sensor interface for the con- nection of a maximum of four...
Permitted storage temperature -30 … 85 °C range Protection class in accordance IP66 with DIN 40050 Housing dimensions 131 x 77.5 x 35.5 mm Body Aluminum housing Weight ≈ 360 g Tab. 10: Other data 24 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
HYDAC. Fig. 3: Type label Description Model For details, see Model code [} 26] Part no. Serial number Date Year/week of production - hardware index Tab. 11: Decoding the model code label BeWa CSI-C-11 4486210 from_V240_up en-us lq 25 / 72...
3 | Product overview HYDAC FILTER SYSTEMS GMBH 3.6.1 Model code The model code of the CSI-C-11 is the following: CSI - C - 11 - 0 - 0 - 0 /- 000 Product series CSI = ConditionSensor Interface Body...
Store the CSI in a clean, dry place, in the supplied packaging as far as is possible. Only remove the packing just before in- stalling the unit. Observe the storage conditions given in Chapter Technical Data [} 23]. BeWa CSI-C-11 4486210 from_V240_up en-us lq 27 / 72...
This chapter provides information on assembly, installation and commissioning. 5.1 Assembling the CSI The CSI-C-11 has an assembly plate with two boreholes for wall mounting or mounting on an electric motor. The position of the CSI can be as required while doing this.
5 | Assembly, installation and commissioning HYDAC FILTER SYSTEMS GMBH 5.2 Connection overview Connect the CSI-C-11 to the sensors and the power supply as shown below. Fig. 8: Connection overview LAN Local Area Network WLAN Wireless Local Area Network Sensor 2 IN Sensor 2...
+ ETH TX- Network (LAN) Ethernet port for data transmission - Fig. 12: LAN ETH RX- Network (LAN) Ethernet port for re- ceiving data - Tab. 15: Pin assignment - LAN 32 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
User name Hydac Password CSI-C-11 Tab. 16: Factory settings of the web server Please ensure: – That your PC or mobile device is located in the same sub- net as the CSI-C-11. 36 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Page 37
HYDAC FILTER SYSTEMS GMBH Assembly, installation and commissioning | 5 – That you are using a suitable Java Script-enabled browser, e.g. Google Chrome, Mozilla Firefox, Apple Sa- fari or Microsoft Edge BeWa CSI-C-11 4486210 from_V240_up en-us lq 37 / 72...
Date for the data logger. Analog 1 ... 4 Parameterizing the connected analog sensors. (Only in CSI-C-11-x-x-1) Channel Type Analog channel type can be selected between: -OFF - 4 - 20 mA, - 0 - 20 mA, - 0 - 10 V 38 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Page 39
Overview of the factory settings [} 41] Sender Address E-mail address of the sender Server Address Address of the mail server Server User Name User name to log into the mail server BeWa CSI-C-11 4486210 from_V240_up en-us lq 39 / 72...
Start Messaging after Delay until the first e-mail Delay between Mes- Delay until the next e-mail sages h Send Mail? Activation of the mail function Tab. 17: Description of the factory settings 40 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
CSI-C-11-x-x-1 Lower Range Upper Range Analog 2 Channel Type OFF Name Analog 2 Unit Lower Range Upper Range Analog 3 Channel Type OFF Name Analog 3 Unit Lower Range Upper Range BeWa CSI-C-11 4486210 from_V240_up en-us lq 41 / 72...
Page 42
Limit 1 Limit 2 Limit 3 Alerting active? false E-Mail Set- Sender Name Hydac CSI-C-11 tings Sender Ad- example@example.com dress Server Address smtp.example.com Server User Hydac Name Server User 12345678 Password 42 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Page 43
HYDAC FILTER SYSTEMS GMBH Factory settings | 6 Recipient Ad- recipient@example.com dress Start Messag- ing after min Delay between Messages h Send E-Mail? false Tab. 18: Factory settings for CSI-C-11-0-0-1/-000 BeWa CSI-C-11 4486210 from_V240_up en-us lq 43 / 72...
– If the status LED is green, the CSI is functioning normally. – If the status LED is red, there is a fault. Details regarding this can be found in the chapter Troubleshooting/fault rec- tification [} 56] Status LED Fig. 16: Status LED 44 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
FluMoS for your ANDROID mobile device is available in the Google Play Store. The data is transmitted exclusively via a wireless connection such as W-LAN or Bluetooth (depending on the device). BeWa CSI-C-11 4486210 from_V240_up en-us lq 45 / 72...
(high byte first). You can set two different formats for the registers, New Format or Old Format . For more details, see Mapping - new format [} 48] or Mapping -old format [} 50]. BeWa CSI-C-11 4486210 from_V240_up en-us lq 47 / 72...
Channel 24 (32bit) 0x0038 + Register offset high byte 0x0039 + Register offset low byte Tab. 19: Mapping - new format The register offset can be parametrized in the dialog menu (factory setting: 0x0000). BeWa CSI-C-11 4486210 from_V240_up en-us lq 49 / 72...
0xA03F low byte Tab. 20: Mapping – old format The allocation of the input register can be called up in the dialog menu. It depends on the sensors actually connected. BeWa CSI-C-11 4486210 from_V240_up en-us lq 51 / 72...
The allocation of the input register can be called up in the dialog menu. It depends on the sensors actually connected. Fig. 17: Example: sensor dialog Sensor 1 + sensor 2 must have different bus ad- dresses. 52 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
7.1.4 Reading measurement protocols via FTP The stored measurement protocols can be read via the FTP of the CSI-C-11. The file can be transferred via the Ethernet with any FTP client software such as FileZilla. To do this, use the user name Anonymous without the password.
Send E-Mail? Fig. 18: Example: E-Mail Settings To ensure that an e-mail is sent via Gmail / Google Mail, adjust the security settings of your Google account. Leave the less secure apps closed. 54 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
SMARTSensor Count in Device Settings, restart CSI, check sensor 2, check cabling Error in initializing Restart the CSI. the analog module. Error in initializing Restart the CSI. the WIFI module. 56 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Page 57
2. Tab. 21: Troubleshooting Signal light - Evaluating / Reading the Error Code To determine the current status of the signal light from the Er- ror Code, mask the respective bits: BeWa CSI-C-11 4486210 from_V240_up en-us lq 57 / 72...
– 1.0 ISO class AS, HLB and MCS --> Measured value ≥ 80% of the limit value (3) Red The measured value has exceeded the set limit value (4) Red Measured values not plausible 58 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
– Dispose of the packaging material in an environmentally friendly manner. – After dismantling the product and separating its various materials into categories, dispose of all parts in an envi- ronmentally friendly manner. BeWa CSI-C-11 4486210 from_V240_up en-us lq 59 / 72...
In this annex, you will find supplementary information on the product. 11.1 Accessories For optimum system integration of the HYDAC ConditionSensor Interface CSI-C-11, the following original ac- cessories are available: Connection cables The following connection cables for sensors are available: Socket <-> plug/open end Length Part no.
Part no. ZBE 45- 3281240 10 m ZBE 45- 3519768 30 m ZBE 45- 4217234 Tab. 25: Connection cable - sensors Connection adapters The following connection adapters for connecting analog sen- sors and signals are available: BeWa CSI-C-11 4486210 from_V240_up en-us lq 61 / 72...
Page 62
HYDAC FILTER SYSTEMS GMBH Length Part no. ZBE CSI 4420372 Tab. 26: Connection adapters Power supply unit The following power supply units are available: Length Part no. 1.8 m 3399939 Tab. 27: Power supply unit 62 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
A3 - analog connection, 5-pin. Description Description +24VDC Supply voltage +24 V DC n.c. Not connected Supply voltage GND Signal Analog voltage signal (e.g. 0 … 10 V) n.c. Not connected Tab. 29: A3 - analog connection, 5-pin. BeWa CSI-C-11 4486210 from_V240_up en-us lq 63 / 72...
Page 64
Supply voltage +24 V DC n.c. Not connected Supply voltage GND n.c. Not connected HYDAC Sensor Interface n.c. Not connected n.c. Not connected n.c. Not connected Tab. 31: S1 / S2 – SMART sensor connection, 8-pin. 64 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Page 65
Sensor 2 IN ....................Fig. 12 LAN......................Fig. 13 Connection example CSI-C-11-0-0-0 ............Fig. 14 Connection example CSI-C-11 - CS1000 - HDA48x6-A - ETS7246-B ..Fig. 15 Connection example ZBE CSI 60............. Fig. 16 Status LED ....................Fig. 17 Example: sensor dialog ................
FluMoS light ing no. 7.603. can read a maximum of 2 sensors via LAN / WLAN or Bluetooth, de- pending on your terminal device. 68 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...
Page 69
Google Play Store. FluMoS mobile can read sensors via WLAN or Bluetooth de- pending on your terminal device. FluMoS professional Abbreviation for "wireless fidelity". Is also a synonym for W-LAN. BeWa CSI-C-11 4486210 from_V240_up en-us lq 69 / 72...
Page 70
Glossary HYDAC FILTER SYSTEMS GMBH WLAN Is the abbreviation for Wireless LAN (Local Area Network). Also a syn- onym for WiFi. 70 / 72 BeWa CSI-C-11 4486210 from_V240_up en-us lq...