Orchestral wizard; best natural sound; midi sound module (49 pages)
Summary of Contents for KETRON SD1000
Page 1
Repair Manual to restore power supply of the sound module Ketron SD1000 from USB port Fault cause: contact failure of an internal switch (pins 2 and 3). See the last page of the instructions (a drawing of the power socket DJK-02A).
Page 2
2. Remove the top cover SD1000. 3. Then using some force pull the volume knob and separate it from stem of the slider.
Page 3
4. Remove the four black screws that secure the circuit board (PCB) to chassis (Use PH1 Phillips Bit for screwdriver) and carefully remove the Board.
5. Pour into a suitable container of ethyl or isopropyl alcohol (if possible, you can use liquid Cleaners/Defluxing for PCB). Immerse in the alcohol corner part of the Board, where the socket external power supply 9VDC (the liquid level should be such that the power socket was fully recessed).