2.
Connect the drain line and run to a suitable
drain avoiding sharp bends and pinching of
the line. Install a condensate trap and prime
with water.
3.
During the system checkout, inspect the
drain line and connections to verify proper
condensate disposal.
Air Filter — Air filters are not provided as an
integral part of this coil, however, a filter must be
installed upstream of the coil and inspected
frequently. When the filter becomes clogged
with dust or lint, it should be replaced (dispos-
able type) or cleaned (washable type). The filter
should be inspected and replaced or cleaned at
least twice during the year, generally at the start
of each heating and cooling season.
Close-Off Plates and Panels — Install the
necessary air close-off plates around the refrig-
erant lines and drain line where required. Rein-
stall all inner and outer panels of the coil case and
furnace that were previously removed to install
the indoor coil.
Refrigerant Charging — These cased indoor
coils are not factory charged with refrigerant.
It will be necessary to evacuate the indoor coil
and line set prior to charging. Refer to the
outdoor unit installation manual for detailed
charges and instructions.
INSTALLER: PLEASE LEAVE THESE
INSTALLATION INSTRUCTIONS WITH
¢708360¬¤
708360B
O'Fallon, MO

6. MAINTENANCE AND SERVICE

Ensure that all electrical power to the
furnace and outdoor (condensing) unit
is off before performing any mainte-
nance or service on the system.
To ensure optimum performance and to mini-
mize possible equipment failure, the following
periodic maintenance should be performed on
this equipment:
1. The air filter installed with the system should
be checked and cleaned or replaced twice per
year.
2. Check the coil, drain pan, and condensate
drain line for cleanliness at the start of each
heating and cooling season. Clean as needed.
Do not operate the system without
having a suitable filter in place in the
return air duct system. Always replace
the filter with the same size and type.
THE HOMEOWNER
!
WARNING:
CAUTION:
!
708360B (Replaces708360A)
Specifications and illustrations subject to change
without notice and without incurring obligations.
Printed in U.S.A. (11/04)