  • Page 1 WCDE-6-NL Mobile Light Tower - 6kW Diesel Generator - 30' Tower - 30 Gal Capacity w/ 60-hr Runtime - NO LAMPS Manual...
  • Page 2: Table Of Contents

    Deployment..........15 4.3.2 Levelling the trailer......... 15 4.3.3 Raising the tower ........15 4.3.4 Lowering the tower ......... 17 4.3.5 Engine operation ........18 4.3.6 Lights ............19 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 2 of 33...
  • Page 3: Main Parts - Hilight V4 W

    Main parts - WCDE-6-NL "The light tower provides an undercarriage ( frame, axle and towbar ). The light tower is very useful for construction sites where neither electricity nor lighting is available." Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 4: Safety Information

    Do not allow water to accumulate around the base of the light tower. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 4 of 33...
  • Page 5: Engine Safety

    Fire hazard. solvents to clean parts. A hot muffler can ignite flammable materials. Keep area around muffler free of debris such as leaves, paper, and cartons. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 5 of 33...
  • Page 6: Service Safety

    ∞ Do not service the light tower if clothing or skin is flammable particles from the exhaust flow of an wet. internal combustion engine. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 6 of 33...
  • Page 7: Assembly

    4. Reinstall the bolts and tighten the nuts fully. Loose parts During transportation, below parts would be disassembled. - Drawbar with towing hitch - Lifting jack Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 7 of 33...
  • Page 8: Light Fixture Wiring

    Light fixture wiring — LAMPS NOT INCLUDED WITH UNIT Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 8 of 33...
  • Page 9: Operation

    Before towing, prepare the light tower as follows. Ensure the tow hitch is properly engaged and locked. 1. Lower the light tower: e Raise, rotate, and lock the front jack in the up position. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 9 of 33...
  • Page 10: During Towing

    5. Crank the jack handle until the jack foot touches the ground and the tow hitch rises up off the tow vehicle. 6. Move the tow vehicle away from the trailer. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 11: Deployment

    When fully extended, d Connect the trailer ground stud to earth ground (see Figure 3.3). Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 12 7. Press the green button (seen in picture to the right) to raise tower. Stop raising tower when you see "STOP" on mast Figure 3.5 Raising the tower Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 12 of 33...
  • Page 13: Lowering The Tower

    • • While lowering the mast, ensure the power cord on the mast collapses freely and does not become pinched or tangled. Figure 3.6 Lowering the tower Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 13 of 33...
  • Page 14: Engine Operation

    Before starting the engine, ensure all power power to the lights or an external device switches (circuit breakers) are in the OFF connected to the power receptacle. position. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 14 of 33...
  • Page 15: Lights

    15 minutes before reaching full brightness. After the lamps are turned off, they will not turn on again until they are cool. The lamps can take up to 15 minutes to cool. Larson Electronics, LLC Larson Electronics, LLC Phone: (800) 369-6671 Phone: (800) 369-6671...
  • Page 16: Maintenance

    Replacement parts Risk of severe burn. Before handling lights, allow For replacement parts, see the parts manual, lights to cool for 15 minutes. document 9829 4074 00. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 16 of 33...
  • Page 17: Wiring Diagrams

    • Turn off power before servicing any component on the light tower. • Only a qualified electrician should service the light tower electrical system. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 17 of 33...
  • Page 18: Maintenance Schedule

    Before carrying out any maintenance activity, check that the ignition switch is in position OFF and that no electrical power is present on the terminals. Service Pak Every 200 hrs Every 1000 hrs Service Pak WCDE-6-NL 3002 6087 40 3002 6087 50 Maintenance schedule (running hrs)
  • Page 19 (7). Change coolant every 2 years, coolant volume is 5L. (8). Gummed or clogged filters means fuel starvation and reduced engine performance. (9). See section "Before starting". (10). Replace all rubber flexibles each 6 years. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 19 of 33...
  • Page 20 Figure 4.4 Comprehensive wiring schematic - 9829 3800 74 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 20 of 33...
  • Page 21 Rotor Stator Excitation coils Capacitor Generator/terminal block Control box lights Wire Colours Black Brown Clear Green Grey Blue Light Blue Orange Pink Purple Shield Violet White Yellow Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 21 of 33...
  • Page 22 Yellow Left stop and turn lights Left stop, turn, and tail lights Brown License plate, tail, and side Side light, amber lights Side light, red White Ground License plate light Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 22 of 33...
  • Page 23 Figure 4.6 - 9829380078 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 23 of 33...
  • Page 24: Dimension Drawing - 9829 3900 86

    Dimension Drawing - 9829 3900 86 Lifting eye(Ø50) Cooling Air Cooling Air Outlet Inlet Frame Drain 1887 [74,291] 990,4 [38,994] 3093 [121,772] Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 24 of 33...
  • Page 25 1577,5 [62,107] Service Door For cleaning cooler Emergency Stop Exhaust Air outlet R686 [27,015] R686 [27,006] 700 [27,559] 920 [36,220] 1349 [53,111] 342,5 [13,484] 342,5 [13,484] Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 25 of 33...
  • Page 26: D900 Axle With Leaf Springs Use And Maintenance Manual

    Check the wheel functioning - is free to rotate, and the wheel can not be detected with axial clearance. • Plug cotter pin. Note: The bearing clearance adjustment too tight can cause bearing damage. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 26 of 33...
  • Page 27: Setting The Lc1003™ Controller

    LED indicates that the unit is in Manual/Start Mode. UP: Is used for navigating the instrumentation, event log and configuration screens and to go to the previous parameter level. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 27 of 33...
  • Page 28: Module Display

    Oil pressure instrumentation screen Display Description Appears when the main Coolant temperature configuration is selected. instrumentation screen Appears when the alternative Fuel sender instrumentation screen configuration is selected. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 28 of 33...
  • Page 29 Engine DTCs (Diagnostic Trouble The animation speed is reduced Codes) if active when running in idle mode. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 29 of 33...
  • Page 30 The engine hours at which the event occurred Icon to indicate the electrical trip or shutdown alarm that has been recorded Current operating state of the module Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 30 of 33...
  • Page 31 0:00:00 Start Time Scheduler (8) Duration 0:00:00 Configuration Parameters – Clock 1001 Time of Day 0:00:00 1002 Day of Month 1003 Month of Year 1004 Year 0000 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 31 of 33...
  • Page 32 2 = monthly week 2 for three seconds. • If for parameter 903 “week” schedule “0” has been selected, parameter 906 is set by default “monthly week 1”. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 32 of 33...
  • Page 33 – > 50 Lux: the floodlights switch off. The luminosity level can be adjusted to a desired higher/lower level, according to the specific operating conditions of the light tower. B1 B2 B1 B2 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 33 of 33...