Operation Guide
Thank you for purchasing the Larson Electronics HAL-24-2L-LV-SOL-80C-
C1D2-20C solar powered Explosion Proof LED light. Follow the steps below
for installing and maintaining your unit.
IMPORTANT
READ CAREFULLY BEFORE OPERATING THIS LIGHT. SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
THIS FIXTURE SHOULD BE INSTALLED BY QUALIFIED TECHNICIANS IN STRICT
ACCORDANCE
WITH
THE
NATIONAL
REQUIREMENTS.
WARNING:
IF UNSURE ABOUT ANY SECTION OF THESE INSTRUCTIONS, CONSULT
A QUALIFIED PROFESSIONAL TO INSTALL THIS DEVICE.
WARNING:
DEVICE IS SUITABLE FOR INSTALLATION IN WET LOCATIONS.
WARNING:
ALTHOUGH WATERPROOF, ANY PART OF THIS UNIT IS NOT DESIGNED
OR INTENDED TO BE SUBMERGED.
WARNING:
DO NOT ALLOW DETACHABLE WIRES TO BECOME SUBMERGED!
IF DROPPED OR DAMAGED, THE UNIT MAY NO LONGER BE WATERPROOF AND
SHOULD BE REPLACED.
HOW SOLAR LIGHT WORKS
Solar light must be placed outdoors. The solar panel collects and converts sunlight
into DC power while the pre-installed rechargeable batteries store the energy to
power the light at night.
Solar light illumination time
It depends on the seasonal sunlight availability in your geographical area under
certain weather conditions. Stronger or longer sunlight hours enable batteries to
store more energy which provides more lighting hours. On the contrary, weaker or
shorter sunlight hours reduce the lighting hours and its brightness as well.
Solar panel mounting locations
Solar panel must be placed outdoor at a location with its solar panel receiving direct
sunlight at least five hours each day. Shadowed locations will not allow batteries to
be fully charged and will reduce both the brightness of the light and the lighting
hours. Precautions (prior to first time use)
1.
To maximize battery capacity, the solar panel should be fully charged by
direct sunlight for five hours before initial use.
2.
Under extremely cold temperatures, the batteries may not charge fully. In
such cases, the Solar Lights may not stay illuminated as long.
MOUNTING SOLAR PANEL
This solar panel includes a permanent mounting system that allows for mounting to
square/round poles or flat surfaces such as a wall or post shown in figure 1.
Position the solar panel in a location that receives the maximum amount of sunlight
throughout the day. This may need adjusted depending on the season. With pole
mounting, loosen the adjustment bolts to fit solar panel onto pole. Once mounted,
tighten bolts snug to secure panel to pole. For surface mounting, remove additional
plate and use the existing mounting holes to mount directly to surface.
HAL-24-2L-LV-SOL-80C-C1D2-20C
ELECTRICAL
CODE
AND
ANY
LOCAL
Larson Electronics LLC
MOUNTING
The light is connected to the
panel by cord. Be sure the
light is connected to the
solar panel and that the
deutsch
connections
are
tight. Run the cord and
mount the light nearby.
DEUTSCH CONNECTION
LAMP INSTALLATION
PRECAUTIONS
Do not install fixture in any classified location where the marked
operating temperature exceeds the ignition temperature of the hazardous
atmospheres.
Consult fixture nameplate for the suitability ambient temperature shown on
the nameplate.
Refer to fixture nameplate for minimum supply wire temperature rating.
Verify that the supply voltage agrees with fixture rating as indicated on
nameplate.
All local and national electrical/building codes must be followed
when installing this lighting fixture. For code interpretation, consult
your local authority.
Product must be used only with glass lens intact and all cap threads
fully engaged. Do not use if lens or fixture is cracked or damaged.
Caution: Only use lamp size, type and /or wattage as shown on fixture nameplate.
We strongly recommend that only a licensed electrician install this product.
WARNING: Make sure that the power is disconnected before installing. This fixture
is heavy and must be mounted to a surface that can structurally support the load.
WARNING: Do not let fixture hang on one bracket at any time. Failing to
comply can result in breakage of end casting or mounting bracket, allowing
the fixture to fall, which can cause serious injury or death.
The mounting brackets are shipped installed on the fixture.
Install the brackets to wall or ceiling with two 3/8" bolts (not supplied) at
center measurements.
Fixture is now ready for mounting.
It is strongly suggested to use two licensed electricians to proceed with the final
mounting of the fixture to avoid any possible personnel injury or damage to the
fixture as the unit is heavy and will be slightly awkward to hold in position and
attach to brackets mounted on wall or ceiling. Depending on mounting height and
Ver.0918-1
1

Advertisement

loading

Summary of Contents for Larson Electronics HAL-24-2L-LV-SOL-80C-C1D2-20C

  • Page 1 Ver.0918-1 MOUNTING Operation Guide The light is connected to the Thank you for purchasing the Larson Electronics HAL-24-2L-LV-SOL-80C- panel by cord. Be sure the light is connected to the C1D2-20C solar powered Explosion Proof LED light. Follow the steps below solar panel and that the for installing and maintaining your unit.
  • Page 2 With up to 5 hours of daily sunlight, this light is designed to function 10 hours. sales@larsonelectronics.com Ensure there are no obstructions that could result in little to no sun reaching the www.larsonelectronics.com panels. Indirect sunlight will extend the charge time. As with all solar powered HAL-24-2L-LV-SOL-80C-C1D2-20C Larson Electronics LLC...