Breville Café Modena ESP6SXL Instruction Booklet page 18

Breville coffeemaker user manual
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING
pROBLEM
Coffee is too weak or watery
Coffee is too cold
No créma
No steam is generated
Milk is not foamy after frothing
18
pOSSIBLE CAUSES
Coffee grind is not fine enough
(use coffee ground for espresso
machines)
Machine not preheated
Cups not preheated
Milk not heated enough
(if making a cappuccino or latte)
Coffee is not tamped (pressed)
firmly enough
Coffee grind is too coarse
Coffee is not fresh
Machine is not turned on
Water tank is empty
Selector Control not in 'STEAM'
position
Steam wand is blocked
(see Care and Cleaning)
Not enough steam
Milk is not fresh and cold