3. OPERATION
3.4.
Molding Cycle
Closing
ON
OFF
ON
OFF
ON
OFF
1
1)
Deactivate Reset CF before mold closing.
2)
Deactivate Reset MP just before the mold is clamped.
3)
Deactivate Reset CP after the mold is completely clamped and before starting injection.
4)
Activate Reset CF, Reset MP and Reset CP during mold opening.
3.5.
Reset
To run a Reset, supply voltage from 12 and 36 V for at least
the reset time selected in the order code (see datasheet,
there are no limits to longer durations) to the Reset input of
the function in question.
For normal function operation, there have to be 0 V (open
contact) at the input.
8
Mold protection
Mold clamping
2
Injection
3
Attention! The duration of the various cycle steps is off-scale.
V
36
30
20
12
10
0
Operative
Opening
Reset CF
Reset MP
Reset CP
4
Reset
Operative
80043_VDA-M_12-2020_ENG
t
t