  • Page 1 VDA-I VARIABLE DIGITAL INLINE AMPLIFIER INSTRUCTION MANUAL Code: 80537...
  • Page 3: Table Of Contents

    Device data ........................................2 Warnings and safety ....................................2 Disposal 2 Disclaimer ........................................2 Copyright ........................................2 GENERAL DESCRIPTION ..........................3 1.1. Profile ........................................3 1.2. VDA-I ........................................4 1.3. Dimensions ......................................4 INSTALLATION ............................. 5 2.1. Mounting the amplifier ..................................5 2.1.1. General installation rules ................................5 2.1.1.1. Protection against infiltration of dust and water ......................5 2.1.1.2.
  • Page 4: Device Data

    Disposal The amplifier VDA-I must be disposed of in conformity to current laws and regulations. If not correctly disposed of, some of the components used in the devices may harm the environment.
  • Page 5: General Description

    GENERAL DESCRIPTION 1.1. Function The variable digital inline amplifier VDA-I converts the signal from strain sensors and load cells into a voltage or current output signal. The VDA-I amplifier can be used in dynamic and static applications. System overview max 15m...
  • Page 6: Vda-I

    1. GENERAL DESCRIPTION 1.2. VDA-I Main features: • Amplifier with fast digital output • For dynamic and static applications • Very high strain gauge bridge offset range • Compact solid aluminium housing (IP65) 1.3. Dimensions VDA-I Dimensions in mm 80537_MAN_VDA-I_10-2017_ENG...
  • Page 7: Installation

    Attention! If even one of the requirements mentioned above (trained technician in, device in perfect condition, correct configuration) is not satisfied, interrupt the installation and contact your Gefran dealer or Gefran Customer Service. 2.1.
  • Page 8: Electrical Connection Sensor Side

    2. INSTALLATION 2.3. Electrical connection sensor side Sensor 2/4 bridge M16 6-pin female Strain gauge 1 Connection Function Strain gauge 1 Strain gauge 1 Strain gauge 2 n.a. Strain gauge 2 Strain gauge 2 n.a. Strain gauge 1 Strain gauge 2 Sensor 4/4 bridge M16 6-pin female Excitation + Connection...
  • Page 9: Operation

    3. OPERATION OPERATION 3.1. Power-on Power is supplied by the controller to which the amplifier is connected; therefore, the amplifier is powered on and off simultaneously with the controller. 3.2. Reset The reset function is used to tare/zero the output signal. To run a Reset, supply voltage from 12 to 36 V for at least 25 ms (there are no limits to longer durations) to the Reset input of the function in question.
  • Page 10: Technical Data

    4. TECHNICAL DATA TECHNICAL DATA 4.1. VDA-I TECHNICAL DATA Output signal VOLTAGE CURRENT Linearity < ± 0.02% FS Zero accuracy < ± 0.1% FS FS accuracy < ± 0.1% FS Accuracy at room temperature (1) < ± 0.2% FS 120…1000 Ω...
  • Page 11: Order Codes

    Example: VDA-I - H - A - N - 2 - 1000 - 00 - HR11 - O Variable digital inline amplifier, Electrical connection sensor side = M16 6-pin half bridge, Electrical connection controller side = M12 5-pin, Output signal = 0...±10 VDC, Bridge = 2/4 (half bridge), Output range of used sensor = 1000µε, Reset type = external high-reset 24V with power-on reset, no peak-hold 5.2.