Download Print this page

Sealey CP9918VHK Instructions page 2

18v cordless hammer drills

Advertisement

1.3.7. DO NOT pull or carry the appliance by attached leads.
1.3.8. DO NOT pull plug from socket by the power cable.
1.3.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty
item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is
damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly
connected, that the cable outer insulation extends beyond the cable restraint and
that the restraint is tight.
1.4.
BATTERY CHARGER SAFETY INSTRUCTIONS
F WARNING! DO NOT attempt to charge any battery other than that supplied for the drill. Other types of batteries may explode!
! All mains electrical supply safety features must be followed as described in Section 1.3. above.
! Disconnect the charger from the mains power supply when not in use.
% DO NOT expose the charger to damp or wet conditions.
% DO NOT pull or carry the charger by the power lead.
% DO NOT operate the charger if it has been dropped, or has received a sharp knock, or is damaged. Take charger to an authorised agent.
% DO NOT dismantle the charger as this may cause damage or personal injury and will invalidate your warranty.
% DO NOT insert foreign objects or material into the hole reserved for the battery pack.
% DO NOT recharge a second battery pack immediately after charging the first. Consecutive charging will overheat the charger. Allow the unit
to cool for 15 minutes before charging the next pack.
% DO NOT attempt to connect two chargers together.
! Store the charger in the same manner as the battery pack, see Section 1.2.
2.
SPECIFICATIONS
Model: CP9918VHK
Chuck size . . . . . . . . . . . . . . . . . . . .10mm
Motor . . . . . . . . . . . . . . . . . . . . . . . . .18V
Speed 1 . . . . . . . . . . . . . . . . . . .0-350rpm
Speed 2 . . . . . . . . . . . . . . . . . .0-1300rpm
Max torque . . . . . . . . . . . . . . . . . . . .18Nm
Impact rate. . . . . . . . . .0-5250/0-19500bpm
Full charge time . . . . . . . . . . . . . . . .1 hour
Model: CP2018VHK
Chuck size . . . . . . . . . . . . . . . . . . . .13mm
Motor . . . . . . . . . . . . . . . . . . . . . . . . .18V
Speed 1 . . . . . . . . . . . . . . . . . . .0-400rpm
Speed 2 . . . . . . . . . . . . . . . . . .0-1450rpm
Max torque . . . . . . . . . . . . . . . . . . . .31Nm
Impact rate . . . . . . . . 0-6000/0-21750bpm
Full charge time . . . . . . . . . . . . . . . .1 hour
3. OPERATING INSTRUCTIONS
Note: When new, the battery pack will have been shipped in a low charge state. It will take longer to charge initially, and several subsequent charges
may also take a little longer, than when the battery pack reaches optimum performance.
3.1.
CHARGING THE BATTERY PACK
3.1.1. To remove the battery pack (fig. 2.A) from the drill, depress the two side release clips (fig.1.9).
F
WARNING! Do not touch the battery terminals.
3.1.2. Place the drill in the carry case and remove the battery charger (fig. 2.B).
3.1.3. The battery pack and charger have the positive (+) and negative (-) terminals marked. Align the
correct terminals and insert the battery (fig. 2). Note: The battery pack is designed so that it will
only enter the charger unit the correct way. When placed in the charger, a very slight downward
pressure will seat the pack firmly into the power terminals.
3.1.4. Connect the charger to mains power and switch on. The red light (fig. 2.C) will glow indicating
that the charge cycle has started.
3.1.5. The red light will remain on until the battery pack is fully charged when it will go out and the green
light (fig. 2.C) will go on. Under normal conditions the battery will take up to 1 hour to fully charge.
3.1.6. When the green light comes on, switch off the charger, unplug from the mains and remove the battery pack.
3.1.7. Place the charger in the carry case. Insert the battery pack into the drill, ready for use.
Note: Attempting to recharge a battery pack immediately after use may result in the red charge light not coming on. In such a case allow the
battery to cool for a time and try again.
Fig. 1
1.
Keyless chuck
2.
Chuck shoulder
3.
Hammer selector
4.
12-step torque control ring - CP9918VHK
4.
22-step torque control ring - CP2018VHK
5.
On/Off variable speed switch
6.
Lock, reverse and forward switch
7.
Two speed switch
8.
18V battery pack
9.
Battery release button (one each side)
Note: On top of the drill is a one-piece tool bit holder.
Immediately to the rear of this holder is a plastic
housing designed to hold a chuck key. Note that, as
the drill is fitted with a keyless chuck, it does not
require, and does not have, a chuck key.
Yellow & Green
Earth Wire
Blue
Neutral
Wire
FUSE RATING 3 AMP
fig. 1
fig. 2
CP9918VHK & CP2018VHK - (3) - 120203
Brown
Live
Wire
Cable
Restraint

Advertisement

loading

This manual is also suitable for:

Cp2018vhk