Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all
electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey dealer. If the product is used in the course of business duties, it
must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.1.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.2.
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct
fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or
8
replaced immediately by a qualified electrician.
1.1.3.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
A) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
B) Connect the BROWN live wire to the live terminal 'L'.
C) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
GENERAL SAFETY
WARNING! Disconnect drill from mains power before changing accessories, servicing or performing any maintenance.
p
Maintain the drill in good condition (use an authorised service agent).
3
WARNING! Keep all guards and holding screws in place, tight and in good working order. Check regularly for damaged parts.
p
A guard or any other part that is damaged must be repaired or replaced before the tool is next used, to ensure that it will
operate properly and perform its intended function. The safety guard is a mandatory fitting where drill is used in premises
covered by the Health & Safety at Work Act.
Check alignment of moving parts and check for possible broken parts.
3
Replace or repair damaged parts. Use genuine Sealey parts only. Non-authorised parts may be dangerous and will invalidate the
3
warranty.
Ensure the set screws of the head frame are screwed tight before using the drill.
3
Secure the drill to the bench/floor to avoid the machine tipping, sliding or walking. Drill is designed for use with drill bits only. No other
3
accessory may be used.
Ensure the chuck is securely fastened to the spindle.
3
Remove adjusting keys and wrenches from the machine and working area before switching on.
3
Use clamps or a vice (not included) to secure the workpiece. Available from your Sealey stockist. DO NOT secure the workpiece by
3
hand.
Refer to speed chart for recommended drilling speeds.
3
WARNING! Always wear approved eye or face protection when operating this drill. Use a dust mask if dust is generated.
p
WARNING! DO NOT wear gloves when drilling.
p
Others in the workplace should be kept at a safe distance from the drill, especially when it is in operation.
3
Keep the work area as childproof as possible by using padlocks and master switches.
3
Keep drill bits clean and sharp for best and safest performance.
3
Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery and contain long hair.
3
Locate the drill in a suitable work area, keep area clean and tidy and free from unrelated materials. Ensure there is adequate lighting.
3
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
3
Avoid unintentional starting.
3
DO NOT use drill for a task it is not designed to perform.
7
DO NOT allow untrained persons to operate the drill.
7
© Jack Sealey Limited
INSTRUCTIONS FOR:
RADIAL PILLAR DRILLS
MODEL No's:
Wear protective
Wear safety
gloves
footwear
Original Language Version
GDM790BR & GDM1630FR
Wear a mask Indoor use only
Replacement fuse rating:
13A
GDM790BR,GDM1630FR Issue; 6(S) - 07/02/18

Advertisement

loading

Summary of Contents for Sealey GDM790BR

  • Page 1 Sealey recommend that an RCD (Residual Current Device) is used with all electrical products. You may obtain an RCD by contacting your local Sealey dealer. If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested.
  • Page 2: Specification

    Model No:........GDM790BR..
  • Page 3: Operation

    5.2. Drill mounting WARNING! For stability and safety it is imperative that the drill base is securely bolted to the workbench (GDM790BR) or floor (GDM1630FR). 5.2.1. Ensure that the mounting surface is capable of supporting the drill together with the weight of the heaviest likely workpiece.
  • Page 4: Maintenance

    With the motor adjustment clamp screw (36) loose and using hand pressure on the motor, set tension so that belt deflection is no more than 10mm each side, at centre span, under finger pressure. Tighten clamp screw (36). Original Language Version © Jack Sealey Limited GDM790BR,GDM1630FR Issue; 6(S) - 07/02/18...
  • Page 5: Troubleshooting

    Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...

This manual is also suitable for: