Summary of Contents for Spectrum F101-P137-BD Series

  • Page 1 SPECTRUM F101-P137X-BD Series F101-P1375-BD F101-P1377-BD F101-P1378-BD Explosion Proof Network Camera Installation Manual F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 2 Spectrum Camera Solutions LLC acknowledges all trademark(s) and the rights of the trademark(s) owned by the company referred to herein. Release Date: 02/05/2020 Document Name F101-P137(5,7,8)-BD INSTALLATIONMANUAL © Copyright 2020 by Spectrum Camera Solutions LLC All rights reserved Revision Record Rev. Description Date...
  • Page 3: Table Of Contents

    Table of Contents Legal Notices and Revision History Inside front cover Page LEGAL NOTICES & DESCRIPTION LABELS STANDARDS AND CERTIFICATIONS DOCUMENT SYMBOLS HOW TO USE THIS MANUAL GENERAL SAFETY AND OPERATING INFORMATION SPECIFICATIONS UNBOXING/HARDWARE WIRING ENTRIES INSTALLATION DISMANTLING AND MAINTENANCE F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 4: Legal Notices & Description

    This document contains information proprietary to Spectrum Camera Solutions LLC with all rights reserved worldwide. Any reproduction or disclosure of this publication, or any part thereof, to persons other than Spectrum Camera Solutions LLC personnel or customers is strictly prohibited, except by written permission of Spectrum Camera Solutions LLC.
  • Page 5: Labels

    Labels F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 6: Standards And Certifications

    STANDARDS & CERTIFICATIONS STANDARDS- The equipment is manufactured in accordance with the IECEX scheme, the ATEX Directive 2014/34/EU and with the following standards : IEC 60079-0:2011 IEC 60079-1:2014 IEC 60079-31:2013 IEC 60529:2013 EN 60079-0:2012 + A11:2013 EN 60079-1:2014 EN 60079-31:2014 EN 60529:1991 + A1:2000 + A2:2013 ANSI/ISA 60079-0:2013 ANSI/UL 60079-1:2015...
  • Page 7: Document Symbols

    DOCUMENT SYMBOLS The following symbols are used throughout this manual to alert users to potential hazards or important information. Failure to heed the warnings and cautions listed herein can lead to injury and equipment damage. Symbol Label Description Consists of conditions, practices, or procedures that WARNING: must be observed to prevent personal injury and/or equipment damage.
  • Page 8: How To Use This Manual

    How to use this Manual General Manual: This manual is intended to be used in conjunction with installed equipment manual from internal equipment manufacturer. Note: In the event of a conflict between the requirements of this general installation manual and the internal equipment manual, the safety and installation procedures described in this manual shall takeprecedence.
  • Page 9: General Safety And Operating Information

    General Safety and Operating Information: General safety and operating information applicable to electrical equipment installed within hazardous locations. This information must be understood by all persons installing, using, or maintaining the electrical equipment. This information is designed to aid personnel in safe installation, operation, and maintenance of the “F"...
  • Page 10 • Use a clean cloth dampened with pure water for cleaning. •Use only accessories that comply with the technical specification of the product. These can be provided by Spectrum or a third party. F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 11 General Safety and Operating Information: Installation: The installation must be realized in accordance with IEC/EN 60079-14, GOST IEC 60079- 14, and/or in accordance with the national requirements. This equipment must be installed and used only by qualified personnel, having knowledge concerning electrical equipment for use in potentially explosive areas containing gas and/or dust.
  • Page 12: Specifications

    SPECIFICATIONS CERTIFICATIONS of Model- F101-P137x-BD FM18US0262X & FM18CA0126X US: Class I Division 1 Groups BCD T5 Ta= -40°C to +55°C, Type 4X, IP66 Class II/III Division 1 Groups EFG Ta= -40°C to +55°C, Type 4X, IP66 Canada: Class I Division 1 Groups BCD T5 Ta= -50°C to +55°C, Type 4X, IP66 Class II/III Division 1 Groups EFG Ta= -50°C to +55°C, Type 4X, IP66 Class I, Zone 1, AEx/Ex db IIB+H2 T5 Gb Ta = -50°C to +55°C, Type 4X, IP66 Zone 21, AEx/Ex tb IIIC T85°C Db Ta = -50°C to +55°C, Type 4X,IP66...
  • Page 13 F1XX Series Casing Material Specifications ALUMINUM 15lbs NOTE: Spectrum Camera Solutions, LLC is NOT responsible for any misuse or improper installation of product, assumes no liability for special or consequential damages caused by use or misuse or improper installation of its products sold and assumes no liability for injury from use or misuse or improper installation of its products or attached products.
  • Page 14: Unboxing/Hardware

    UNBOXING F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 15 HARDWARE 1 (QTY 1) F1XX- CAMERA ASSEMBLY 2 (QTY 1) SUN SHIELD 3 (1 SET) .250-20 HEX SCREW 4 (1 SET) SPLIT LOCK WASHER 5 F1XX-WM (WALL MOUNT NOT INCLUDED) 6 (QTY 2) SUN SHIELD STOP 7. ( 1 SET) .3125-18 PAN HEAD SCREW 8.
  • Page 16: Wiring Entries

    WIRING ENTRIES ¾” NPT PORT ¾” NPT PORT Conduit Entries are ¾ inch NPT Use appropriate adapter to keep ingress protection CAUTION: Ensure power is disconnected prior to connecting F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 17: Installation

    INSTALLATION 2. Loosen the set screw on the housing and remove ¼-20 hex screws from the sunshield and then lift the sunshield from the camera housing. Tabletop Figure 2.1 ¼-20 hex screws Figure 2.1 screw Figure 2.2 -If wall mounted, remove sunshield stop. F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 18 INSTALLATION 4. Push release on terminal block and insert positive 12-24 VDC/VAC connection into terminal block (+A) , release to secure. Do the same for negative dc connection into terminal block (-B). Figure 4. F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 19 INSTALLATION 5.The product shall be grounded either through a shielded network cable (STP) or other appropriate method. 1.Crimp RJ-45 using T568B color code then plug Cat6 POE into the RJ-45 Port located on the back of the Camera. 2. Internal grounding screw 5850-6 SLBHUC 10-24x ¼ ZS ZGR Shielded RJ-45 Plug for STP cable Figure 5.2...
  • Page 20 INSTALLATION 7. Ensure threads and gaskets are free of dirt and debris. 8. Reinstall F1XX end cap by hand, tighten by turning clockwise until hand tight and the gasket is seated Figure 8. 9. Tighten both set screws on the end cap and the lens cap of the housing. Figure 9.
  • Page 21: Dismantling And Maintenance

    For more information about the server report, see the product´s setup pages or contact Spectrum support. The battery should not be replaced unless required, but if the battery does need replacing, contact Spectrum support at support@spectrumcamera.com...
  • Page 22: F101-P137(5,7,8)-Bd Rev 2 114309212018 F1Xx

    EU Declaration of Conformity Doc No. F1xx-10107152019 Spectrum Camera Solutions, 2014/34/EU Spectrum Camera Solutions declares that under our sole responsibility that the product (s) listed below conform to the relevant provisions of 2014/34/EU of November 08, 2018 F101-P137(5,7,8)-BD REV 2 114309212018 F1XX...
  • Page 23 F1XX-WM F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 24 SD-PMA POLE MOUNTADAPTER HARDWARE QTY 4 M10-1.75 18-8 Bolts QTY 2 12in all thread with nuts and washers QTY 2 A1612 sides F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 25 SD-CM CORNER MOUNT HARDWARE- QTY 4 7/16-20 18-8 Bolts F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 26 SD-VM VIBRATION MOUNT HARDWARE- QTY 4 7/16-20 18-8 Bolts FRONT F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 27 SD-SO STANDOFF MOUNT HARDWARE- QTY 4 7/16-20 18-8 Bolts FRONT BACK F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...
  • Page 28 ASSEMBLY MOUNTS F1XX-WM+SD-VM+SD-SO+ SD-PMA F1XX-WM+SD-PMA F101-P137(5,7,8)-BD REV 2 114309212018 F1XX SERIES INSTALLATION REV-2A...